Bose MR-J2S- B instruction manual 7Auxiliary equipment and options, 8Performing EMC tests

Models: MR-J2S- B

1 172
Download 172 pages 5.2 Kb
Page 10
Image 10
(7)Auxiliary equipment and options

(7)Auxiliary equipment and options

(a)The no-fuse breaker and magnetic contactor used should be the EN or IEC standard-compliant products of the models described in Section 12.2.2.

(b)The sizes of the cables described in Section 12.2.1 meet the following requirements. To meet the other requirements, follow Table 5 and Appendix C in EN60204-1.

Ambient temperature: 40 (104) [(8)Performing EMC testsManual background (Manual backgroundManual background)]

Sheath: PVC (polyvinyl chloride)

Installed on wall surface or open table tray

(c)Use the EMC filter for noise reduction. The radio noise filter (FR-BIF) is not required.

(8)Performing EMC tests

When EMC tests are run on a machine/device into which the servo amplifier has been installed, it must conform to the electromagnetic compatibility (immunity/emission) standards after it has satisfied the operating environment/electrical equipment specifications.

For the other EMC directive guidelines on the servo amplifier, refer to the EMC Installation Guidelines(IB(NA)67310).

A - 9

Page 10
Image 10
Bose MR-J2S- B instruction manual 7Auxiliary equipment and options, 8Performing EMC tests