Appendix B Product IDs for the Cisco CRS 8-Slot Line Card Chassis
Optional Line Card, PLIM, SIP, and SPA Product IDs
| Table B-2 | Line Card Component Product IDs |   | 
|   |   |   |   | 
| Component |   | Product ID | Description | 
|   |   |   |   | 
| MSC1 |   | CRS-MSC-B(=), | Cisco CRS Layer 3 modular service card | 
|   |   | CRS-MSC-140G(=) | (every MSC must have an associated PLIM) | 
|   |   | CRS-MSC-X (200G) |   | 
|   |   |   | Cisco CRS Layer 3 forwarding processor | 
| FP card |   | FP40 | (every FP must have an associated PLIM) | 
|   |   | 
| LSP card |   | FP-140 | Cisco label switch processor | 
|   | CRS-FP-X (200G) | (every LSP must have an associated PLIM) | 
|   |   | 
|   |   | CRS-LSP |   | 
|   |   |   | 
| MSC impedance carrier | CRS-MSC-IMPEDANCE(=) | Blank card carrier for each empty MSC slot | 
|   |   |   | (required for EMI compliance and cooling) | 
|   |   |   |   | 
1. Refer to the product data sheet for ordering details.
| Table B-3 | PLIM Component Product IDs |   |   | 
|   |   |   |   | 
| Component |   | Product ID | Description | 
|   |   |   | 
| 1xOC-768 PLIM | 1OC768-POS-SR(=) | 1-port OC-768c/STM-256c PLIM, with | 
|   |   |   | short-reach optics (POS) | 
|   |   |   | 
| 4xOC-192 PLIM | 4OC192-POS/DPT-LR(=) | 4-port OC-192c/STM-64c PLIM, with | 
|   |   |   | long-reach optics (POS or DPT) | 
|   |   |   |   | 
|   |   | 4OC192-POS/DPT-IR(=) | 4-port OC-192c/STM-64c PLIM, with | 
|   |   |   | intermediate-reach optics (POS or DPT) | 
|   |   |   |   | 
|   |   | 4OC192-POS/DPT-SR(=) | 4-port OC-192c/STM-64c PLIM, with | 
|   |   |   | short-reach optics (POS or DPT) | 
|   |   |   |   | 
|   |   | 4OC192-POS/DPT-VS(=) | 4-port OC-192c/STM-64c PLIM, with | 
|   |   |   | very-short-reach optics (POS or DPT) | 
|   |   |   | 
| 16xOC-48 PLIM | 16OC48-POS/DPT(=) | OC-48c/STM-16c PLIM, uses small form-factor | 
|   |   | POM-OC48-LR2-LC-C(=) | pluggable (SFP) modules (POS or DPT) | 
|   |   |   |   | 
|   |   | POM-OC48-SR-LC-C(=) | The PLIM uses 1 to 16 single-mode, long- and | 
|   |   |   | short-reach optic modules (mixing allowed): | 
|   |   |   | • | Long-reach optics (POM-OC48-LR2-LC-C=) | 
|   |   |   | • | Short-reach optics (POM-OC48-SR-LC-C=) | 
|   |   |   | 
| 8x10-GE XENPAK | 8-10GBE(=) | 10-GE PLIM, uses XENPAK optic modules. | 
| PLIM |   | CRS-XENPAK10GB-LR(=) | The PLIM uses 1 to 8 single-mode, long-reach | 
|   |   | 
|   |   |   | optic modules: | 
|   |   |   | Long-reach optics (CRS-XENPAK10GB-LR=) | 
|   |   |   |   | 
| 8x10-GE and |   | 8-10GBE-WL-XFP(=) | 10-GE PLIM, uses XFP optic modules. | 
| 4x10-GE XFP |   | 4-10GBE-WL-XFP(=) | These PLIMs use 1 to 8 (or 1 to 4) single-mode, | 
| PLIMs |   | 
|   |   | XFP optic modules. | 
|   |   |   | 
|   |   |   |   |   | 
Cisco CRS Carrier Routing System 8-Slot Line Card Chassis Installation Guide