Chapter 2 Installing and Removing Power Components

Power Component Information Common to Two Types of Power System

Figure 2-8 45-Degree DC Power Cable Lug

All measurements in inches

2.11 REF

Ø0.27

0.60+/- .02

+/- .04

2 holes

 

 

0.25

 

 

0.63

 

 

0.38

 

 

+/- .04

+/- .02

 

REF

.10

0.88

+/- .04

1.18 REF

45° +/- 5°

2.11 REF

310355

+/- .01

Note In the modular configuration power system, DC power cables have a torque value of 20 in.-lb (2.26 N-m) and chassis ground cable connectors have a torque value of 30 in.-lb (3.39 N-m).

For additional power details, see Appendix A, “Cisco CRS Carrier Routing System 8-Slot Line Card Chassis Specifications” or Cisco CRS Carrier Routing System 8-Slot Line Card Chassis System Description.

AC Power Systems

Each AC powered chassis contains two fixed configuration AC PDUs or two modular configuration AC power shelves for 2N redundancy.

In the fixed configuration power system, each PDU accepts one AC power rectifier. The PDUs and AC power rectifiers are field replaceable.

In the modular configuration power system, each power shelf can contain up to three AC PMs. The power shelves and the AC PMs are field replaceable.

Note Depending on the hardware deployed at your site, your system may not consume the maximum power supplied by the power system.