Reference Manual

00809-0100-4530, Rev BA July 2009

Rosemount 5300 Series

Application Example 2

Radar Level Gauge, Level value in percent (%)

The maximum level in the tank is 46 ft. (14 m). The level value is displayed in percentage of the full span (see Figure 5-14).

Figure 5-14. Situation Diagram

Table 5-10. Analog Input Function Block Configuration for a Level Transmitter where level output is scaled between 0-100%

100%

46ft.

(14 m)

0%

Solution

Table 5-10lists the appropriate configuration settings, and Figure 5-15illustrates the correct function block configuration.

Parameter

Configured Values

L_TYPE

Indirect

XD_SCALE

0 to 14 m

OUT_SCALE

0 to 100%

CHANNEL

CH1: Level

Figure 5-15. Function Block Diagram for a Level Transmitter where level output is scaled between 0-100%

Level Measurement - percent

 

 

 

 

 

 

 

 

OUT_D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AI Function Block

 

 

 

 

 

 

 

 

 

 

OUT

 

0 to 100%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-43

Page 115
Image 115
Emerson Process Management 5300 Radar Level Gauge, Level value in percent %, 100% 46 ft 14 m, Level Measurement percent