Remote Housing Measuring Range

Table A-2. Remote Housing measuring range

This table shows the maximum recommended measuring range with Remote Housing for different RH lengths, installation types, Dielectric Constants, and probe types.

 

 

Dielectric

Rigid Single

Rigid Single

Flexible Single

Coaxial

Rigid Twin

Flexible Twin

 

 

Constant

8 mm

13 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chamber / pipe

1.4

4 ft (1.25 m)

15 ft (4.5 m)(1)

33 ft (10 m)(1) (2)

 

10 ft (3 m)(1)

33 ft (10 m)(1) (2)

1 m

installations ≤ 4 in.

2

10 ft (3 m)(1)

15 ft (4.5 m)(1)

33 ft (10 m)(1) (2)

 

10 ft (3 m)(1)

33 ft (10 m)(1) (2)

(100 mm)

80

10 ft (3 m)

15 ft (4.5 m)(1)

33 ft (10 m)(1) (2)

19 ft

10 ft (3 m)(1)

33 ft (10 m)(1) (2)

Remote

 

1.4

4 ft (1.25 m)

4 ft (1.25 m)

4 ft (1.25 m)

(6 m)

4 ft (1.25 m)

4 ft (1.25 m)

 

Housing

 

Tank installations

2

4 ft (1.25 m)

4 ft (1.25 m)

4 ft (1.25 m)

 

4 ft (1.25 m)

98 ft (30 m)(1)

 

 

80

10 ft (3 m)(1)

10 ft (3 m)(1)

159 ft (48.5 m)(1)

 

10 ft (3 m)(1)

159 ft (48.5 m)(1)

 

Chamber / pipe

1.4

9 ft (2.75 m)

15 ft (4.5 m)(1)

33 ft (10 m)(1) (2)

 

10 ft (3 m)(1)

33 ft (10 m)(1) (2)

2 m

installations ≤ 4 in.

2

10 ft (3 m)(1)

15 ft (4.5 m)(1)

33 ft (10 m)(1) (2)

 

10 ft (3 m)(1)

33 ft (10 m)(1) (2)

(100 mm)

80

10 ft (3 m)

15 ft (4.5 m)

33 ft (10 m)(1) (2)

19 ft

10 ft (3 m)(1)

33 ft (10 m)(1) (2)

Remote

 

1.4

9 ft (2.75 m)

9 ft (2.75 m)

9 ft (2.75 m)

(6 m)

9 ft (2.75 m)

9 ft (2.75 m)

 

Housing

 

Tank installations

2

9 ft (2.75 m)

9 ft (2.75 m)

9 ft (2.75 m)

 

9 ft (2.75 m)

98 ft (30 m)(1)

 

 

80

10 ft (3 m)(1)

10 ft (3 m)(1)

154 ft (47 m)(1)

 

10 ft (3 m)(1)

154 ft (47 m)(1)

 

Chamber / pipe

1.4

 

15 ft (4.5 m)

33 ft (10 m)(1) (2)

 

 

33 ft (10 m)(1) (2)

3 m

installations ≤ 4 in.

2

 

15 ft (4.5 m)

33 ft (10 m)(1) (2)

 

 

33 ft (10 m)(1) (2)

(100 mm)

80

 

15 ft (4.5 m)

33 ft (10 m)(1) (2)

19 ft

10 ft (3 m)(1)

33 ft (10 m)(1) (2)

Remote

 

1.4

10 ft (3 m)

14 ft (4.25 m)

14 ft (4.25 m)

(6 m)

14 ft (4.25 m)

 

Housing

 

 

 

Tank installations

2

 

14 ft (4.25 m)

14 ft (4.25 m)

 

 

98 ft (30 m)(1)

 

 

80

 

15 ft (4.5 m)(1)

149 ft (45.5 m)(1)

 

 

149 ft (45.5 m)(1)

(1)Accuracy may be affected up to + 1.2 in. (30 mm).

(2)Required chamber/pipe size is 3 or 4 in. (75 -100 mm).

A-8

Page 192
Image 192
Emerson Process Management 5300 manual Remote Housing Measuring Range