Reference Manual

00809-0100-4530, Rev BA July 2009

Rosemount 5300 Series

EN:

316L SST according to EN 1092-1 Table 18, material group 13E0. Standard: Max. 302 °F/580 psig

(150 °C/40 Bar). HP/HTHP/C: Up to PN 320.

Alloy C-276 according to EN 1092-1 table 18 material group 12E0. HP/HTHP: Up to PN320.

Fisher & Masoneilan:

According to ANSI B16.5 Table 2-2.3. Standard: Max. 302 °F/580 psig (150 °C/40 Bar).

HP/HTHP/C: 32 °F/1199 psig (20 °C/82.7 Bar). Up to Class 600, Table 2.3.

JIS:

According to JIS B2220 Table 2.3 Standard: 10K/20K/150C.

HP/C: 10K/20K/200C.

HTHP: 10K/20K/400C

Ambient Temperature

For Alloy C-276 HTHP/HP probes with flange plate design is available up to Class 600/PN 63.

When the Rosemount 5300 is installed in high or low temperature applications, it is important that the maximum/minimum ambient temperature is considered. Nozzle insulation for the HTHP version should not exceed 4 in. (10 cm).

The diagram below shows the ambient temperature vs. process temperature:

Figure A-5. Ambient temperature vs. process temperature.

 

Ambient Temperature °F (°C)

 

Process

 

Temperature °F (°C)

 

-40 (-40)

-320 (-196)

-17 (-27)

 

-40 (-40)

NOTE!

The maximum ambient temperature also depends on hazardous locations certfications.

A-7

Page 191
Image 191
Emerson Process Management 5300 manual Ambient Temperature, Fisher & Masoneilan, Jis