Interface Status

Interface Status messages that may appear on the Integral Display, on the

375 Handheld Communicator, in DeltaV, or in RRM are shown in Table 7-8:

Table 7-8. Interface status.

Message

Description

Action

Interface not OK

The interface measurement is not OK.

Check other interface status messages

 

 

for reason.

Interface not found

No interface available

No action needed.

 

Interface threshold to high

Adjust Interface threshold, see “Interface

 

 

Pulse not Found” on page 7-8.

Can't measure interface on

Interface cannot be measured when the

Change the probe mounting or turn off

horizontal probe

probe is horizontally mounted.

interface measurement by changing the

 

 

measurement mode.

Can't handle max possible

With the current configuration, the

Accept the limitation or change the tank

interface thickness

maximum measurement range is too

environment and device configuration.

 

short to guarantee that the interface echo

 

 

can always be found.

 

Interface thickness close to

The interface is close to the limit where it

No action needed but the interface echo

max range

will be lost due to the limited maximum

may be lost if the upper product thickness

 

measurement range.

increases.

Interface set to max thickness

No interface echo found. The upper

No action needed.

 

product thickness is set the maximum

 

 

value of the current level measurement.

 

Interface thickness greater

The interface was found below the probe

The Upper Product Dielectric Constant is

than probe length

end.

probably incorrect.

Volume Calculation Status

Volume Calculation Status messages that may appear on the Integral Display, on the 375 Handheld Communicator, or in RRM are shown in Table 7-9:

Table 7-9. Volume status.

Message

Description

Action

Level is below lowest strapping

The measured level is below the

For a correct volume calculation in

point.

lowest point in the given strapping

this region, change the strapping

 

table.

table.

Level is above highest strapping

The measured level is above the

For a correct volume calculation in

point.

highest point in the given strapping

this region, change the strapping

 

table.

table.

Level out of range.

The measured level is outside the

Check if the correct tank type is

 

given tank shape.

chosen and check the configured

 

 

Tank Height.

Strap table length not valid.

The configured strap table length is

Change the strapping table size to a

 

too small or too large.

valid number of strapping points. A

 

 

maximum number of 20 strapping

 

 

points can be entered.

Strap table not valid.

The strapping table is not correctly

Check that both level and volume

 

configured.

values in the strapping table are

 

 

increasing with strapping table index.

Level not valid.

The measured level is not valid. No

Check Measurement Status, Warning

 

volume value can be calculated.

and Error Messages.

Volume configuration missing.

No volume calculation method is

Do a volume configuration.

 

chosen.

 

Volume not valid.

The calculated volume is not valid.

Check the other volume status

 

 

messages for the reason.