Reference Manual

00809-0100-4530, Rev BA July 2009

Rosemount 5300 Series

Figure B-15. Approval Label Canadian Standards Association (CSA) Foundation Fieldbus model

I6 Intrinsically Safe Ex ia.

Class I, Division 1, Groups A, B, C and D.

Temperature code T4.

FOUNDATION Fieldbus model: Ui=30 Vdc, Ii=300 mA, Pi=1.3 W,

Ci=0 nF, Li=0 H.

Control Drawing: 9240 030-937.

Ambient temperature limits: -50 °C to + 60 °C

Figure B-16. Approval Label Canadian Standards Association (CSA) FISCO model

IF Intrinsically Safe Ex ia.

Class I, Division 1, Groups A, B, C and D.

Temperature code T4.

FISCO model: Ui=17.5 Vdc, Ii=380 mA, Pi=5.32 W,

Ci=0 nF, Li=0 H.

Control Drawing: 9240 030-937.

Ambient temperature limits: -50 °C to + 60 °C