FACTORY MUTUAL (FM) APPROVALS

Intrinsic Safety

Figure B-9. Approval Labels Factory Mutual (FM) HART model

The Rosemount 5300 Series Guided Wave Radar Level Transmitter that have the following labels attached have been certified to comply with the requirements of the approval agencies noted.

I5 Intrinsically Safe for Class I, II, III, Division 1, Groups A, B, C, D, E, F and G.

Class I, Zone 0, AEX ia IIC T4 when installed per Control Drawing: 9240030-936.

Non-incendive for Class I, Division 2, Groups A, B, C and D. Suitable for Class II, III, Division 2, Groups F and G.

4-20 mA/HART model: Ui=30 V, Ii=130 mA, Pi=1.0 W, Ci=7.26 nF, Li=0. Max operation 42.4 V, 25 mA.

Temperature code T4.

Ambient Temperature Limits: -50 °C to + 70 °C.