Reference Manual

00809-0100-4530, Rev BA July 2009

Rosemount 5300 Series

Appendix F Level Transducer Block

OVERVIEW

Figure F-1. Transducer Block Diagram

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page F-1 Parameters and Descriptions . . . . . . . . . . . . . . . . . . . . . . page F-2 Supported Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page F-8 Diagnostics Device Errors . . . . . . . . . . . . . . . . . . . . . . . . . page F-9

This section contains information on the 5300 Level Transducer Block (TB). Descriptions of all Transducer Block parameters, errors, and diagnostics are listed.

 

 

 

 

 

Channel

1

 

Linearization

Temperature Compensation

 

Units/Ranging

Channel

 

Damping

2

 

Channel

Digital

3

Channel

Signal

4

Conversion

Channel

 

5

 

Channel

 

6

 

 

 

 

 

 

 

 

 

 

 

 

Diagnostics

 

 

TB

 

 

 

 

 

 

 

 

Definition

The transducer block contains the actual measurement data, including a level

 

and distance reading. Channels 1–16 are assigned to these measurements

 

(see Figure F-1). The transducer block includes information about sensor

 

type, engineering units, and all parameters needed to configure the

 

transmitter.