Parameter

Index

 

Description

Number

 

 

 

 

 

 

 

SAVE_CONFIG_NOW

61

Allows the user to optionally save all non-volatile information immediately.

 

 

 

SECURITY_IO

65

Status of security switch.

SELF_TEST

59

Instructs resource block to perform self-test. Tests are device specific.

 

 

 

SET_FSTATE

29

Allows the FAIL_SAFE condition to be manually initiated by selecting Set.

SHED_RCAS

26

Time duration at which to give up on computer writes to function block RCas locations.

 

 

Shed from RCas shall never happen when SHED_ROUT = 0

 

 

 

SHED_ROUT

27

Time duration at which to give up on computer writes to function block ROut locations.

 

 

Shed from ROut shall never happen when SHED_ROUT = 0

SIMULATE_IO

64

Status of simulate switch.

 

 

 

SIMULATE_STATE

66

The state of the simulate switch:

 

 

0

= Uninitialized

 

 

1

= Switch off, simulation not allowed

 

 

2

= Switch on, simulation not allowed (need to cycle jumper/switch)

 

 

3

= Switch on, simulation allowed

ST_REV

01

The revision level of the static data associated with the function block.

 

 

 

 

START_WITH_DEFAULTS

63

0

= Uninitialized

 

 

1

= do not power-up with NV defaults

 

 

2

= power-up with default node address

 

 

3

= power-up with default pd_tag and node address

 

 

4

= power-up with default data for the entire communications stack (no application data)

STRATEGY

03

The strategy field can be used to identify grouping of blocks.

 

 

 

SUMMARY_STATUS

56

An enumerated value of repair analysis.

TAG_DESC

02

The user description of the intended application of the block.

 

 

 

TEST_RW

08

Read/write test parameter - used only for conformance testing.

UPDATE_EVT

35

This alert is generated by any change to the static data.

 

 

 

WRITE_ALM

40

This alert is generated if the write lock parameter is cleared.

WRITE_LOCK

34

When hardware write protection is selected, WRITE_LOCK becomes an indicator of the

 

 

jumper setting and is unavailable for software write protection.

 

 

When software write lock is selected, and WRITE_LOCK is set, no writings from

 

 

anywhere else are allowed, except to clear WRITE_LOCK. Block input will continue to be

 

 

updated.

 

 

 

WRITE_PRI

39

Priority of the alarm generated by clearing the write lock.

XD_OPTION

44

Indicates which transducer block licensing options are enabled.

 

 

 

 

I-4

Page 302
Image 302