Emerson Process Management 5300 manual Electric, Mechanical

Models: 5300

1 324
Download 324 pages 46.88 Kb
Page 186
Image 186

Rosemount 5300 Series

Reference Manual

00809-0100-4530, Rev BA July 2009

Display / Configuration (continued)

FOUNDATION Fieldbus

Link Master (LAS).

Class (Basic or Link

 

Master)

 

FOUNDATION Fieldbus

AI-block: 30 ms. PID-block: 40 ms.

Block Execution Time

ARTH-, ISEL-, OSPL-block: 65 ms. CHAR-block: 75 ms.

FOUNDATION Fieldbus

No.

Instantiation

 

Conforming FOUNDATION

ITK 5.0.

Fieldbus

 

FOUNDATION Fieldbus

Yes.

PlantWeb® Alert Support

 

Damping

0-60 s (2 s, default value).

Electric

 

 

 

Power Supply

HART: 16-42.4 Vdc (16-30 Vdc in IS applications, 20-42.4 Vdc in Explosion-proof / Flameproof applications).

 

FOUNDATION Fieldbus: 9-32 Vdc (9-30 Vdc in IS applications, and 16-32 Vdc in Explosionproof / Flameproof

 

applications).

 

FISCO, IS applications: 9-17.5 Vdc.

Internal Power

< 50 mW in normal operation.

Consumption

 

Output

HART 4-20 mA current loop or FOUNDATION Fieldbus.

Quiescent Current Draw (

21 mA

FOUNDATION Fieldbus)

 

Signal on Alarm

Standard : Low = 3.75 mA, High = 21.75 mA.

 

Namur NE 43: Low = 3.60 mA, High = 22.50 mA.

Saturation Levels

Standard: Low = 3.9 mA, High = 20.8 mA.

 

Namur NE 43: Low = 3.8 mA, High = 20.5 mA.

IS Parameters

See Appendix B: Product Certifications.

Cable Entry

½ - 14 NPT for cable glands or conduit entries.

 

Optional: M20 x 1.5 conduit / cable adapter, M12 4-pin male eurofast® connector or A size Mini 4-pin male

 

minifast® connector.

Output Cabling

Twisted shielded pairs, 18-12 AWG.

Mechanical

 

 

 

Probes

Coaxial: 1.3 ft (0.4 m) to 19.7 ft (6 m).

 

Rigid Twin Lead: 1.3 ft (0.4 m) to 9.8 ft (3 m).

 

Flexible Twin Lead: 3.3 ft (1 m) to 164 ft (50 m).

 

Rigid Single Lead (0.3 in./8 mm): 1.3 ft (0.4 m) to 9.8 ft (3 m)

 

Rigid Single Lead (0.5 in./13 mm): 1.3 ft (0.4 m) to 14.8 ft (4.5 m)

 

Flexible Single Lead: 3.3 ft (1 m) to 164 ft (50 m).

Tensile Strength

4 mm Flexible Single Lead probe (model code 5A, 5B): 2698 lb (12 kN)

 

6 mm Flexible Single Lead probe (model code 6A, 6B): 6519 lb (29 kN)

 

Flexible Twin Lead probe: 2023 lb (9 kN).

Collapse Load

4 mm Flexible Single Lead probe (model code 5A, 5B): 3597 lb (16 kN)

 

6 mm Flexible Single Lead probe (model code 6A, 6B): 7868 lb (35 kN)

Sideway Capacity

Coaxial: 73.7 ft lbf or 3.7 lb at 19.7 ft (100 Nm or 1.67 kg at 6 m).

 

Rigid Twin Lead: 2.2 ft lbf or 0.22 lb at 9.8 ft (3 Nm or 0.1 kg at 3 m).

 

Rigid Single Lead: 4.4 ft lbf or 0.44 lb at 9.8 ft (6 Nm or 0.2 kg at 3 m).

Material Exposed to Tank

• 316L SST (EN 1.4404), PTFE, PFA(5) and O-ring materials (Standard Probe, Material model code 1) or

Atmosphere

• Alloy C-276 (UNS N10276), PTFE, PFA(5) and O-ring materials (Standard Probe, Material model code 2) or

Alloy 400 (UNS N04400), PTFE, PFA(5) and O-ring materials (Standard Probe, Material model code 3)

PTFE(6) (Standard Probe, Material model code 7) or

PTFE(6), 316 L SST (EN 1.4404) and O-ring materials (Standard Probe, Material model code 8)

316L SST (EN 1.4404), Ceramic (Al2O3), Graphite, Inconel (HTHP Probe, Material model code 1)

Alloy C-276 (UNS N10276), Ceramic (Al2O3), Graphite, Inconel (HTHP Probe, Material model code 2 and H)

316L SST (EN 1.4404), Ceramic (Al2O3), Graphite, PFA, PTFE, Inconel (HP Probe, Material model code 1)

Alloy C-276 (UNS N10276), Ceramic (Al2O3), Graphite, PFA, PTFE, Inconel (HP Probe, Material model code 2 and H)

316L SST (EN 1.4404), Ceramic (Al2O3), Graphite, PFA, PTFE, Inconel (C Probe, Material model code 1) See “Ordering Information” on page A-21.

A-2

Page 186
Image 186
Emerson Process Management 5300 manual Electric, Mechanical