Rosemount 5300 Series

Reference Manual

00809-0100-4530, Rev BA July 2009

Installing the RRM software for HART communication

To install the Rosemount Radar Master:

1.Insert the installation CD into your CD-ROM drive.

2.If the installation program is not automatically started, choose Run from the Windows Start bar.

3.Type D:\RRM\Setup.exe, where D is the CD-ROM drive.

4.Follow the instructions on the screen.

5.Make sure that HART is chosen as default protocol.

6.For Windows 2000/XP set COM Port Buffers to 1, see page 5-15.

Getting Started

1.From the Start menu click Programs>Rosemount>Rosemount Radar Master or click the RRM icon in the Windows workspace.

2.If the Search Device window did not appear automatically, choose menu option Device>Search.

3.In the Search Device window, choose communication protocol HART, and click the Start Scan button (click the Advanced button if you want to specify start and stop address).

Now RRM searches for the transmitter.

4.After a while the Search Device window presents a list of found transmitters.

5.Select the desired transmitter and press OK to connect. If communication does not work, check that the correct COM port is connected to the computer and that the COM port is properly configured, see “Specifying the COM Port” on page 5-15.You may also check in the Communication Preferences window that HART communication is enabled.

6.In the RRM Status Bar verify that RRM communicates with the transmitter:

RRM communicates with the transmitter

No communication with the transmitter

5-14