The configuration of a Rosemount 5300 transmitter is normally a simple and straight-forward task. The complete configuration of a Rosemount 5300 transmitter includes Basic Configuration, Echo Tuning and Advanced Configuration. This section describes Basic Configuration.

If the transmitter is pre-configured at the factory according to the ordering specifications in the Configuration Data Sheet, no further Basic Configuration is required unless tank conditions have changed. The Rosemount 5300 Series supports a set of advanced configuration options as well, which can be used to handle special tank conditions and applications.

The Basic Configuration includes parameters for a standard configuration which is sufficient in most cases. The Basic Configuration comprises the following items:

Measurement Units

Tank Configuration

-Tank Geometry

-Environment

-Volume

Analog Output

Amplitude thresholds can be adjusted in order to handle special situations when, for example, objects in the tank cause disturbing echoes that are stronger than the surface echo. A useful function is the so called Amplitude Threshold Curve (ATC) which lets you filter out single disturbing echoes. See Section 7: Service and Troubleshooting, and Appendix C: Advanced Configuration for more information.

It is possible to specify the variables to be presented on the Display Panel. See also Section 6: Operation.

For some applications, further device specific configuration is needed in addition to the Basic Configuration. This may be due to product properties or tank shape. See Appendix C: Advanced Configuration for more information.

There are several tools available for the configuration of a Rosemount 5300 transmitter:

Rosemount Radar Master (RRM). Note that RRM is recommended for advanced configuration features.

See “Basic Configuration Using Rosemount Radar Master” on

page 5-13for information on how to use RRM for configuration of the 5300 Series

Rosemount 375 Field Communicator.

See “Basic Configuration Using a 375 Field Communicator” on page 5-11for the Field Communicator Menu Tree

AMS Suite software (for HART). See “Basic Configuration Using AMS Suite (HART)” on page 5-30

DeltaV (only for Foundation Fieldbus). See “Basic Configuration Using DeltaV” on page 5-31

Other tools that support Electronic Device Description Language (EDDL) functionality