00809-0100-4530, Rev BA July
Reference Manual
Page
North American Response Center
Page
Table of Contents
Configuration
Electrical Installation
Operation
Service Troubleshooting
Safety Instrumented Systems 4-20 mA only
Appendix a
Reference Data
Appendix F
Appendix C
Appendix G
Appendix H
Appendix
Section Introduction
Safety Messages
Explosions could result in death or serious injury
Electrical shock could cause death or serious injury
Manual Overview
Service Support
Product RECYCLING/DISPOSAL
Transmitter Overview
Signal Amplitude Reference Pulse Level Interface Level Time
Applications
Tank
5303
Components of the Transmitter
½ NPT
Lead
M50 nut Cable Remote Connection
Dual Compartment Housing Bolt Bracket
4-20 mA
System Architecture
20 mA/HART
Minimum load resistance 250 Ω within the loop is required
Host/DCS system e.g. DeltaV
Foundation Fieldbus system architecture
Rigid Single Flexible Single Coaxial
Probe Selection Guide
Flexible Twin
Tank Environment Considerations
Dielectric
Transition Zones
Flexible Single Lead Coaxial
Constant
Sticky applications, periodic cleaning may be required
Process Characteristics
Coating
Bridging Foam Vapor Boiling Hydrocarbons
Measuring Range
Interface
Minimum Dielectric Constant at Maximum Measuring Range
Upper product dielectric constant
Flexible Single Lead Product
Heating Coils, Agitators Tank Shape
Vessel Characteristics
Emulsion Layers
Lower product
Installation
Procedure
Follow these steps for proper installation
Rosemount 5300 Series
Process leaks could result in death or serious injury
Mechanical Installation
Rosemount 5300 Series
Considerations
Mounting
Process Connection
Threaded Connection
Recommended
Single Rigid/Flexible Coaxial
Nozzle Diameter D
Diameter D1 Recommended
Long Stud
Installation of Single Lead Probes Non-metallic Vessels
Metal flange Ø2 Metal sheet
In./DN50
Installation in Concrete Silos
Considerations for Solid Applications
Metal
Material
Mounting in Chamber/ Still Pipe
Polypropylene
Pellets Cement
Probe Type Recommended Diameter Minimum Diameter
Rigid Single
Rosemount 5300 Series
Replacing a Displacer An Existing Displacer Chamber
Considerations when changing to Rosemount
Required Probe Length Depending on Chamber Manufacturers
Rosemount 5300 benefits
Free Space
Inlet pipe Agitator Heating coils
Mounting Position
Recommended Mounting for Solids
Ambient Temperature F C
Insulated Tanks
Hthp version Tank insulation
Qualified personnel perform the installation
Flange Connection
Transmitter head Nut Bolts Flange Probe Gasket Tank flange
Transmitter head Nut
Threaded Connection
Flange nut Bolts Probe Gasket Tank flange
Nut Tank connection Probe Sealant on threads or
Tri-Clamp Connection
Bracket Mounting
Fasten the housing support to the bracket
Mount the bracket to the pole
Connect the transmitter head on the probe
Hthp Coaxial and Ptfe probes must not be shortened
Shortening the Probe
Flexible Twin/Single Lead
Rigid Single Lead
Rigid Twin Lead
Hthp coaxial probe must not
Coaxial
Be cut in field
Centering piece is
Flexible Twin/Single Lead probe with weight and magnet
Flexible Twin/Single Lead probe with weight and ring
Weight with internal threads M8x14 Ring Magnet
Anchoring
Rigid Twin Lead probe
Coaxial probe
Flexible Single Lead probe
Drain
Solid Applications
Alternative chuck for Flexible Single Lead probes
≥ 1cm/m
Mounting a Centering Disc on Flexible Single Probes
Mounting a Centering Disc for Pipe Installations
Mounting a Centering Disc on Rigid Single Probes
Rigid Single Lead probe 13 mm
Secure the split pin
Bushing
Rigid Single Lead probe 8 mm
Rosemount 5300 Series
Electrical Installation
Avoid contact with leads and terminals
Hazardous Areas
CABLE/CONDUIT Entries Grounding Cable Selection
Hart
Power Requirements Maximum Loop Resistance
Current
75 mA
Connecting the Transmitter
Non-Intrinsically Safe Output
Field
Communicator Radar Transmitter AMS Suite Hart modem
Is parameters1
Ui=30 Ii=130 mA Pi=1 W Ci=7.26 nF Li=0
Approved is Barrier
Power Requirements
Power supplies
Approval Type Power Supply Vdc
Grounding Foundation Fieldbus
Shield Wire Ground
Connecting Fieldbus Devices
Non-Intrinsically Safe Output
Ui=30 Ii=300 mA Pi=1.5 W ATEX, 1.3 W FM Ci=7.26 nF Li=0
Fisco is parameters
Ui=17.5 Ii=380 mA Pi=5.32 W Ci=0 Li=0
Tri-Loop Hart to analog converter
Optional Devices
DIN Rail Mounted Hart Tri-Loop Burst Input to Tri-Loop
Intrinsically Safe Barrier
Field Signal Indicator
Section Configuration
Overview
Rosemount 5300 Series
Measurement Units Tank and Probe Geometry
Basic Configuration Parameters
Mounting Type
Tank Height
Inner Diameter
Nozzle Height
Tank Environment
Measurement Mode
Hold Off/Upper Null Zone
Rapid Level Changes
Volume Configuration
Tank Type
Strapping Table
Vertical Cylinder
Standard Tank Shapes
Horizontal Cylinder
Vertical Bullet
Upper/Lower Range Value
Output Source/Primary Variable
Level MA Saturation Values MA Alarm Value
Alarm Mode
High 20.8 mA
High 20.5 mA 22.5 mA
Basic Configuration Using a 375 Field Communicator
Setup
Diagnostics/Tools
Process Variables
System Requirements Help In RRM
Basic Configuration Using Rosemount Radar Master
Hardware
Software
Getting Started
Installing the RRM software for Hart communication
To set the COM port buffers
Specifying the COM Port
Click the OK button
Restart the computer
Installing the RRM Software for Foundation Fieldbus
Select the Measurement Units tab
Specifying Measurement Units
Using the Setup Functions
Run Wizard
Guided Setup
General Information
Device Properties
Probe
Geometry Hart command 2, 1 Foundation Fieldbus parameter
Dielectric Constant/Dielectric Range
Process Conditions
Rosemount 5300 Series
Volume Offset
Volume
Tank Diameter
Tank Length
Analog Output Hart
Finish Configuration Wizard
Device Specific Configuration
Backup
Restart the Transmitter
View Measured Values
Rosemount 5300 Series
Configure/Setup
Basic Configuration Using AMS Suite Hart
Basic Configuration Using Deltav
Rosemount 5300 Series
Rosemount 5300 Series
Transducer 1100MEASMODE
See Volume Configuration on page 5-7for more information
Volume Offset Foundation Fieldbus parameter
Diameter Foundation Fieldbus parameter
Tank Length Foundation Fieldbus parameter
Assigning Device Tag and Node Address
Foundation Fieldbus Overview
Foundation Fieldbus Block Operation
Advanced Configuration Transducer Block
Level Transducer Block
Register Transducer Block
Analog Input Block
Function Block Summary
Outd
Direct
Configure the AI Block
Indirect
AI Block
Xdscale and Outscale
Indirect Square Root
Ltype is Direct
Ltype is Indirect
Signal Strength
Temperature
Engineering Units
Level Rate
Parameter Configured Values
Solution
Application Example
Radar Level Transmitter, Level Value
Radar Level Gauge, Level value in percent %
100% 46 ft 14 m
Level Measurement percent
Level Measurement
100% 10ft 3 m 33 ft 10 m
Function Block Interface Level Measurement
Function Block
TRI-LOOP Hart to Analog Converter
Variables Assignment
Variable Units
To turn off the Burst Mode
DIN Rail Mounted
Control Room
Hart MULTI-DROP Configuration
Rosemount 5300 Series
Section Operation
Error messages are listed in section LCD Error Messages on
Using the Display Panel
Viewing Measurement Data
Measurement value
Using Rosemount Radar Master RRM
Using a Handheld Communicator
Device Config General
Specifying Display Panel Variables
LCD tab
Using AMS
Using DeltaV
LCD Parameters
LCD parameters and presentation on display
Parameter Presentation on display Description
Presentation Analog Output value in RRM
Viewing Measurement Data in RRM
Viewing Measurement Data in AMS Suite
Level values Interface Level values
Viewing Measurement Data in DeltaV
Rosemount 5300 Series
Foundation Fieldbus Error Messages
Service and Troubleshooting
Explosions could result in death or serious injury
Distance, m
Analyzing the Measurement Signal
Rosemount 5300 Series
Amplitude, mV
Surface Pulse not Found
Probe End Projection
Amplitude, mV Disturbing Echo Actual surface
As product Surface Distance, m
Disturbance Echo Handling
Measurement signal
Amplitude Threshold Curve
Disturbances at the Top of the Tank
Interface Pulse not Found
Amplitude, mV Distance, m
Signal Quality Metrics
Using the Echo Curve Analyzer
Using the Rosemount Radar Master
Device Config Tools
Configuration Mode Tab
Measurement Output
Measure and Learn Set threshold
View/Record ModeTab
Record tank spectra Play continuously updates the spectrum
Advanced
Play
To adjust the amplitude thresholds
Threshold Settings
Record Tank Spectra
Viewing the Echo Curve
Rosemount 5300 Series
Interface Measurements with Fully Submerged Probes
Interface Distance
Product Level is ignored Interface Level is measured
Analog Output Calibration
Level and Distance Calibration
Distance calibration
Level calibration
Reference Point Distance Reference Gauge Height Level
12. Distance and Level calibration
Update rate Start Log
Logging Measurement Data
Browse
Backup File Reader
Backing UP Transmitter Configuration
Configuration Report
Reset to Factory Settings
Choose the Factory Settings option
Factory Settings
Rosemount Radar Master
Diagnostics
Hart command
DeltaV
Status
Choose the Simulation Mode option
RRM choose menu option ToolsSimulation Mode
Simulation Mode
Mode
Write Protecting a Transmitter
Enter Service Mode in RRM
Choose the Unlock/Lock Device option
Unlock/Lock
Viewing Input and Holding Registers
Nut Put the protection
Removing the Transmitter Head
Plug here
Put the protection Nut
Changing a Probe
Probe and Firmware Compatibility
Firmware Version
Check Firmware and Probe Version
Check the manufacturing date on the transmitter head label
Check the R2, VC marking on the probe
Transmitter Head Nut Process Seal Probe
Changing the Probe
Near Zone
GWR Series Near Zone
Firmware Version Rigid Probes Flexible Probes
Troubleshooting Chart
Diagnostic Messages
Symptom Possible cause Action
3for information on possible causes
Surface Pulse Not Found on
Message Description Action
Device Status
Errors
Normally result in Analog Output alarm
Errors are indicated in RRM in the Diagnostics window
RRM, warnings are indicated in the Diagnostics window
Alarms
Measurement Status
Rosemount 5300 Series
Interface Status
Volume Calculation Status
Analog Output Status
375 Handheld Communicator, or in RRM are shown in Table
10. Analog Output Status
For more information on errors, see Errors on
LCD Error Messages
Error Message
Error Message Description
Example
Code Error
Flashing LED
Seconds
Resource Block
Block Errors
13lists conditions reported in the Blockerr parameter
14. Resource Block Summarystatus messages
Analog Input AI Function Block
Power Up
17. Transducer Block Xderr messages
Condition Condition Name and Description
Symptom Possible Causes Recommended Actions
00809-0100-4530, Rev BA July 19. Troubleshooting AI block
Section
Safety Instrumented Systems 4-20 mA only
Rosemount 5300 Series
Applicable Models
Safety Device QS Option
Skill Level of Personnel
Prior-Use Option Model Codes
Damping
Functional Specifications Installation
Minimum input voltage Ui at different currents
Hazardous Current
Operation and Maintenance
Alarm and Saturation Levels
Write Protection Site Acceptance
General
Proof test
References Specifications Failure Rate Data Useful Lifetime
Inspection
Spare Parts Terms and Definitions
Rosemount 5300 Series
Appendix a Reference Data
Display / Configuration
General
Measuring Performance
Mechanical
Electric
Environment
Process Temperature and Pressure Rating
Temperature F C
Pressure psig bar
Temperature F C
Flange Rating Standards
Flange Connection Rating
Ambient Temperature
Fisher & Masoneilan
JIS
Remote
Remote Housing Measuring Range
Dimensions are in inches millimeters
Dimensional
Drawings
Probe Type 4A, 4B
½ 14 NPT Optional adapters M20x1.5, eurofast and minifast
10.1
NPT 1/1½/2 inch
In. s60
10.1 15.6 In. s52 ½ in. s60
Probe with Flange Connection
Probe Type 5A, 5B
Rosemount 5300 Series
Option W2 140 4 and 6 mm
Figure A-11. Flexible Single Lead with threaded connection
Probe Type 3A, 3B
Figure A-12. Coaxial probe with flange connection
10.1 In. s52 15.6 ½ in. s60
≤ 20 feet 6 m 1½ inch
½ inch
Probe Type 1A
NPT 1½ / 2 inch 10.2 ½ 14 NPT
S60 ≤ 10 feet 3 m 24 6 Ø 0.31 ½ in. s52 In. s60 10.2 Flange
≤ 164 feet 50 m Flange 10.2
Probe Type 2A
Pipe diameter max 2.5 in mm
Figure A-16. Bracket mounting
Figure A-17. Remote housing
Model Code 5301 and 5302 Level and/or Interface in Liquids
Ordering Information
Code Probe Length Units
Code Probe Type Process Connection Probe Lengths
Code Total Probe Length 13 feet/m
Code Total Probe Length 13 in./cm
JIS Flanges15
EN DIN Flanges15
Connections14 Probe Type
Tri-Clamp Fittings14 Probe Type
Code Hazardous Locations Certifications
Special Configuration Software
Code Options
Qx Special Certifications
Remote Housing Mounting
PlantWeb Diagnostic Functionality
Centering Discs Outer Diameter
Consolidate to Chamber
Model Code 5303, Level for Solids
Code Signal Output
Model Product Description
Code Total Probe Length 5 feet/m
EN DIN Flanges7
Flanges6
JIS Flanges7
Connections6 Probe Type
Special Certifications
3.2 ft. Remote Housing Mounting Cable and Bracket
Spare Parts
Spare parts list Transmitter head Model 5301/5302/5303
CSA Fisco Intrinsic Safety2
Spare parts list Probe Model 5301/5302/5303
Code Material of Construction4 Process Probe Type
For other o-ring materials
Code Total Probe Length 12 in./cm
Code Total Probe Length 12 feet/m
Flanges15
EN DIN Flanges13
JIS Flanges13
EN DIN Flanges14
Connections15 Probe Type
Tri-Clamp Fittings15 Probe Type
In. Centering disc21 In. Centering disc PTFE22
Remote Housing / Bracket Mounting
Other accessories
Other spares
Centering discs1
Rosemount 5300 Series
Rosemount 5300 Series
Appendix B Product Certifications
EU Conformity
Intrinsic Safety
European Atex Directive Information
Special Conditions for Safe Use
Rosemount 5300 Series
Rosemount 5300 Series
Flameproof
Rosemount 5300 Series
E3/HART I3/HART
E3/FIELDBUS I3/FIELDBUS
Rosemount 5300 Series
Factory Mutual FM Approvals
Rosemount 5300 Series
Explosion Proof
Dual seal maintenance
This product meets the Dual Seal Requirements of ANSI/ISA
Dual seal annunciation
Rosemount 5300 Series
Explosion Proof
Conditions of Certification
Iecex Approval
Rosemount 5300 Series
Rosemount 5300 Series
Flameproof
Rosemount 5300 Series
Combination Approvals Approval Drawings
Rosemount 5300 Series
Rosemount 5300 Series
Rosemount 5300 Series
Rosemount 5300 Series
Appendix C Advanced Configuration
Rosemount 5300 Series
Distance Offset Tank Height Product Level
Upper Reference Point Transmitter
Handling of Disturbances from Nozzle
Using the Trim Near Zone Function
Trim Near Zone
Trim Near Zone
Click Trim Near Zone
Figure C-3. Trim Near Zone using RRM
Rosemount 5300 Series
Figure C-4. Upper Null Zone
Changing the Upper Null Zone
Interface Threshold
Automatic Surface Threshold
Reference Threshold
Probe End Threshold
Full Tank Threshold Offset
Probe END Projection
Probe End pulse
Actual Probe End position Apparent Probe
Optional configurations
Figure C-10. Echo Tracking
Echo Tracking
Damping
Use Automatic Echo Tracking Settings
Static Vapor Compensation
Dielectric Constant Settings
Lower Product
Vapor Dielectric Constant Lower Product Dielectric
Temperature oF/oC Dielectric constant Pressure Pressure Bar
Dynamic Vapor Compensation
Dielectric constant
Vapor Compensation
VC marking on tank seal
Figure C-14. Single Rigid Hthp with VC marking on the probe
Figure C-15. Minimum requirements
Installation Setup
Click the Calibrate Vapor Compensation button
To calibrate Dynamic Vapor Compensation
Following diagnostics measurements are available
Signal Quality Metrics
Surface Threshold=
Curve ATC
Option and select the Signal Quality Metrics tab
Viewing Signal Quality
Diagnostics Suite
Metrics in RRM
Signal Quality Surface / Noise Margin
Appendix D Remote Mounting
Remote HOUSING, NEW Units
Connect the transmitter head on the housing support
Mount the probe housing on the probe
Remote CONNECTION, Field Retrofit
Remote Housing Configuration
Appendix E Performing Proof Test
Performing Proof Test Field Communicator
Hart Sequence 2, 6
Enable write protection
Hart Sequence 3, 2, 1, 2
Range 4mA
Alarm Mode AOut Loop test
RRM Select Setup, Output from the menu
Rosemount Radar Master RRM
RRM Tools / Echo Curve
Rosemount 5300 Series
AMS Select Device Diagnostics / Tools from the left menu
AMS Click Configure / Setup / Echo Curve
AMS Select Configure / Setup, Analog Output from the menu
AMS Suite
Rosemount 5300 Series
Definition
Appendix F Level Transducer Block
Transmitter
Channel Linearization
Parameters Descriptions
Channel Definitions
Channels for the Rosemount 5300 Series are the following
Table F-1. Channel Assignments
Transducertype
Geomtankheight
Maxupperproductthickness
Table F-3. Probe Type
Table F-5. Environment
00809-0100-4530, Rev BA July Table F-4. Device Mode
Table F-6. Presentation
Table F-7. LCD Parameters
Table F-8. Product Dielectrical Range
Table F-9. Measurement Mode
Unit Codes
Supported Units
Bit Number Value Description Corrective action
Diagnostics Device Errors
Rosemount 5300 Series
Table G-1. Register Access Transducer Block Parameters
Register Access Transducer Block Parameters
Appendix G Register Transducer Block
Parameter Index Description
Parameter Index Description Number
DBREG2FLOAT
Rosemount 5300 Series
Appendix H Advanced Configuration Transducer Block
Advanced Configuration Transducer Block Parameters
Volume measurements
Amplitudethresholdcurve
Volstraptablelength
Rosemount 5300 Series
Appendix I Resource Transducer Block
Overview Parameters and Descriptions
Definition
Cycletype
Maintpri
Saveconfignow
PlantWeb Alerts
Advisory Alarms
Maintenabled
Alarm Priority
Process Alarms Recommended Actions for PlantWeb Alerts
Priority
RB.RECOMMENDEDACTION
Figure J-1. Analog-Input Block
Appendix J Analog-Input Block
Parameter Index Units Description Number
Alarmhys
Device
Simulation
Damping
Figure J-2. Analog Input Function Block Schematic
Signal Conversion
Modes
Block Errors
Table J-2. Blockerr Conditions
Condition Condition Name and Description Number
Priority Number
Alarm Detection
Status Handling
Advanced Features
Configure the AI Block
Table J-5. Level Rate
Table J-6. Temperature
Table J-7. Signal Strength
Table J-8. Volume
Rosemount 5300 Series
Numerics
Index
Ioopts
Varindex
Index-4
Page
Emerson Process Management