Rosemount 5300 Series

Reference Manual

00809-0100-4530, Rev BA July 2009

Parameter

Index Number

Description

TCL

37

This parameter is used for User Defined probes only. Please

 

 

contact Emerson Process Management Service Department

 

 

for more information

PROPAGATION_FACTOR

38

This parameter is used for User Defined probes only. Please

 

 

contact Emerson Process Management Service Department

 

 

for more information

REF_PULSE_AMPL

39

This parameter is used for User Defined probes only. Please

 

 

contact Emerson Process Management Service Department

 

 

for more information

GEOM_TANK_HEIGHT

40

Tank Height (R)

GEOM_HOLD_OFF_DIST

41

Hold off distance

VAPOR_DC

42

Enter the dielectric constant for the vapor gas in the tank. For

 

 

air at 20 degC and atmospherical pressure the vapor DC is

 

 

close to 1, but for high pressure/high temperature applications

 

 

the DC may increase and affect the accuracy of the

 

 

measurement

UPPER_PRODUCT_DC

43

Enter the Upper Product Dielectric Constant (DC) as dielectric

 

 

accurate as possible. This value affects the accuracy of the

 

 

interface level measurement

LOWER_PRODUCT_DC_RANGE

44

Enter the range of the dielectric constant (DC) for the lower

 

 

product in the tank. If you are uncertain about the value for

 

 

this parameter or are changing product in the tank on a

 

 

regular basis choose Unknown

PRODUCT_DIELEC_RANGE

45

Enter the range of the Product DC for the product in the tank.

 

 

If you are uncertain about the value for this parameter or are

 

 

changing product in the tank on a regular basis choose

 

 

Unknown

MEAS_MODE

46

Select the Measurement Mode to use in the device. Some

 

 

modes require software options to be enabled in the device.

 

 

You can upgrade the device to enable more software options

DAMP_VALUE

47

Damping value

GEOM_OFFSET_DIST

48

Distance Offset

GEOM_CALIBRATION_DIST

49

Calibration Distance

LCD_SETTINGS

50

 

LCD_PARAMETERS

51

Parameters to show

LCD_LANGUAGE

52

Language on display

LCD_LENGTH_UNIT

53

Length unit on display

LCD_VOLUME_UNIT

54

Volume unit on display

LCD_TEMPERATURE_UNIT

55

Temperature unit on display

LCD_VELOCITY_UNIT

56

Velocity unit on display

MAX_INTERNAL_TEMPERATURE

57

The maximum temperature that has been measured inside

 

 

the device during operation

MIN_INTERNAL_TEMPERATURE

58

The minimum temperature that has been measured inside the

 

 

device during operation

OPERATION TIME

59

The total number of hours the device has been in operation

ENV_ENVIRONMENT

60

Process Condition

ENV_PRESENTATION

61

Tank Presentation

ENV_DEVICE_MODE

62

Service mode

ENV_WRITE_PROTECT

63

Write protect

DIAGN_DEVICE_ALERT

64

Errors, Warnings, Status, Plant web alerts

DIAGN_VERSION

65

Gauge SW version

DIAGN_REVISION

66

P1451 revision

DIAGN_DEVICE_ID

67

Device ID for the gauge.

DIAGN_DEVICE_MODEL

68

Type of 5300. LF or HF

STATS_ATTEMPTS

69

The total number of messages sent to the transducer A/D

 

 

board

STATS_FAILURES

70

The total number of failed A/D board message attempts

F-4

Page 284
Image 284
Emerson Process Management 5300 manual Geomtankheight