NEC 120Lg manual Replacing the Rear Cooling Fan

Models: 120Lg

1 204
Download 204 pages 18.51 Kb
Page 122
Image 122

Replacing the Rear Cooling Fan

1.Observe the safety and ESD precautions listed under General Information and Static Precautions at the beginning of this chapter.

2.Open the front bezel of your system's cabinet.

3.Shutdown the operating system (OS).

4.Press the power on/off switch on the front panel of the server (see Front View in Chapter 1). The power-on LED goes out.

5.Power off the peripheral devices.

6.Unplug the system power cord(s) from the AC wall outlet(s).

Note: If the system power cord is connected to a power control unit such as an UPS (Uninterruptible Power Supply), refer to the UPS user's guide for proper power-off procedures.

7.Remove the left-hand side access panel of the chassis following procedures previously described in this chapter.

!CAUTION

For proper cooling and airflow, do not operate the system with the side access panel removed. Always replace the panel before powering on the system.

8.Remove the processor air duct. See Processor Air Duct Removal earlier in this chapter.

9.Disconnect the rear cooling fan cable to the system board. See Figure 4-53.

Fan Connector

Figure 4-53. Rear Cooling Fan System Board Connector

4-56 Disassembly and Reassembly