![](/images/new-backgrounds/1194348/194348311x1.webp)
STATUS lamp | Description | Procedure | |
indication | |||
|
| ||
On (green) | The server is operating normally. | – | |
Flashing | • The server is operating with the | Check the AC POWER lamp | |
(green) | memory, CPU, or power supply | indication on the rear panel of the | |
| unit in degraded state. | server. | |
| • A | Identify the device in degraded state | |
| often occurred. | by using the BIOS setup utility | |
|
| "SETUP," and replace it as soon as | |
|
| possible. | |
Off | The power is off. | – | |
| POST is in progress. | Wait for a while. The STATUS lamp | |
|
| turns green when POST is completed. | |
| A CPU error occurred. | Turn the power off and then turn it on. | |
| A CPU temperature alarm was | If the POST screen displays an error | |
| detected. | message, take notes of the message, | |
| A timeout occurred when the time | and contact your sales representative. | |
| set for the watchdog timer arrived. |
| |
| A CPU bus error occurred. |
| |
| A memory dump request is made. | Wait until the memory dump is | |
|
| completed. | |
On (amber) | A temperature alarm was detected. | Check if the internal fans are clean | |
|
| and if the fan units are firmly | |
|
| connected. | |
|
| If the STATUS lamp indication does | |
|
| not change when the fans are normal, | |
|
| contact your sales representative. | |
| A voltage alarm was detected. | Contact your sales representative. | |
| All the power supply units failed. |
| |
Flashing | Either of the following was detected | Connect the power cord to supply | |
(amber) | in the redundant power | power. If the power supply unit is | |
| configuration: | faulty, contact your sales | |
| • AC power not supplied to one of | representative. | |
| the two power supply units |
| |
| • Failure of one of the two power |
| |
| supply units |
| |
| A fan alarm was detected. | Check if the fan units are firmly | |
|
| connected. | |
|
| If the STATUS lamp indication does | |
|
| not change when the fans are normal, | |
|
| contact your sales representative. | |
| A temperature warning was | Check if the internal fans are clean | |
| detected. | and if the fan units are firmly | |
|
| connected. | |
|
| If the STATUS lamp indication does | |
|
| not change when the fans are normal, | |
|
| contact your sales representative. |