Installi ng the BayS tac k 450 Swit ch
302401-D Rev 00 2-3

Installati o n Procedure

This section provides the requirements and instructions for installing the
BayStack 450 switch on a flat surface or in a standard 19-inch utility rack. If you
install the switch in a rack, ground the rack to the same grounding electrode used
by t he po wer service in the area . The gro und path must be permane nt and must not
exceed 1 ohm of resistance from the rack to the grounding electrode.

Installing the BayStack 450 Switch on a Flat Surface

Note: An optional wall mount kit is available for the BayStack 450 switch
(Order Number Al2018003). See your Nortel Networks sales representative
for order ing informat ion. Installation instructions are provided with the wall
mount kit.
Caution: When this device is installed in a stack on a shelf or tabletop, the
accumulated weight of the port cables increases with the height of the shelf or
tabletop.
Achtung: Wenn dieses Gerät in einem Stapel auf einem Tisch oder einem
Regalboden installiert wird, erhöht sich das Gesamtgewicht der
Schnittstellenkabel mit der Höhe des Regalbodens oder Tisches.
Attention: Si l'appareil est posé dans un rack ou sur une étagère, notez bien
que le poids du câblage réseau augmente avec la hauteur de l'installation.
Precaución: Cuando este dispos it ivo se i nst ala api lado en un es tante o s obr e
una mesa, el peso acumulado de los cables de los puertos aumenta según la
altura del estante o de la mesa.
Attenzione: Quando il dispositivo vi ene i ns ta ll at o in st ack su un ri pia no o s u
un tavolo, il peso dei cavi connessi alle porte aumenta in proporzione
all' altezza del ripiano o del tavolo.
kombk.book Page 3 Tuesday, June 29, 1999 3:25 PM