Using the BayStack 450 10/100/1000 Series Switch

IP Configuration/Setup

The IP Configuration/Setup screen (Figure 3-3) allows you to set or modify the BayStack 450 switch IP configuration parameters. Data that you enter in the user-configurable fields takes effect as soon as you press [Enter].

Choose IP Configuration/Setup (or press i) from the main menu to open the IP Configuration/Setup screen.

IP Configuration/Setup

BootP Request Mode: [ BootP Disabled

]

 

 

Configurable

In Use

 

Last BootP

 

-------------------

---------------

---------------

In-Band Stack IP Address:

[ 0.0.0.0 ]

 

 

0.0.0.0

In-Band Switch IP Address: [ 0.0.0.0 ]

 

 

0.0.0.0

In-Band Subnet Mask:

[ 0.0.0.0 ]

0.0.0.0

 

0.0.0.0

Default Gateway:

[ 0.0.0.0 ]

0.0.0.0

 

0.0.0.0

Use space bar to display choices, press <Return> or <Enter> to select choice. Press Ctrl-R to return to previous menu. Press Ctrl-C to return to Main Menu.

Figure 3-3. IP Configuration/Setup Screen

Note: The read-only fields in this screen are updated based on the BootP mode specified in the BootP Request Mode field. (See “ Choosing a BootP Request Mode” on page 3-10 for more information.)

Table 3-2 describes the IP Configuration/Setup screen fields.

3-8

302401-D Rev 00

Page 140