Nortel Networks 450 manual System Characteristics Screen Fields

Models: 450

1 290
Download 290 pages 47.47 Kb
Page 148
Image 148

Using the BayStack 450 10/100/1000 Series Switch

Table 3-4.

System Characteristics Screen Fields

 

 

 

Field

Description

 

 

 

Operation Mode

Read-only field that indicates the operation mode of the unit, for example:

 

• When the unit is part of a stack configuration, the (read-only) field indicates the

 

unit is operational in a stack, and lists the current unit number of this switch. In

 

this example (see Figure 3-5 on page 3-15), the current unit number is Unit 2.

 

• When the unit is not part of a stack configuration (operating standalone), the

 

read-only field indicates the unit is operating as a switch. When in this operation

 

mode, the Size of Stack and Base Unit fields (see following description) do not

 

appear.

 

Size of Stack

This read-only field only appears when the switch is participating in a stack

 

configuration. This field indicates the number of units configured in the stack

 

configuration (1 to 8 units maximum).

Base Unit

This read-only field only appears when the switch is participating in a stack

 

configuration. This field indicates the unit number of the switch that is currently

 

operating as the base unit.

MAC Address

The MAC address of the BayStack 450 switch or, when the switch is participating in a

 

stack configuration, the MAC address of the stack configuration.

Reset Count

A read-only field that indicates the number of resets since the operational firmware

 

was first loaded on the switch.

 

Default Value

1

 

Range

0 to 232 -1

Last Reset Type

A read-only field that indicates the last type of reset.

 

Default Value

Power Cycle

 

Range

Power Cycle, Software Download, Management Reset,

 

 

Management Factory Reset

Power Status

A read-only field that indicates the current power source (primary, RPSU, or both).

 

Default Value

Primary Power

 

Range

Primary Power, Redundant Power, Primary and Redundant Power

Local MDA Type

A read-only field that indicates the MDA type that is configured in this unit.

sysDescr

A read-only field that specifies the hardware and software version.

 

 

(continued)

3-16

302401-D Rev 00

Page 148
Image 148
Nortel Networks 450 manual System Characteristics Screen Fields