Using the BayStack 450 10/100/1000 Series Switch

BayStack 450-12F Switch

Cas

 

 

 

 

 

 

 

 

 

 

Pwr Up

1

2

3

4

5

6

7

8

9

10 11 12

Link

Status Dwn

F Dx

RPSU Base

Activity

BayStack 450-12F

= Dual color LED

BS45071A

Figure 1-4. BayStack 450-12F LED Display Panel

Table 1-1.

BayStack 450 Switch LED Descriptions

 

 

 

 

 

Label

Type

Color

State

Meaning

 

 

 

 

 

Pwr

Power status

Green

On

DC power is available to the switch’s internal circuitry.

 

 

 

Off

No AC power to switch or power supply failed.

Status

System status

Green

On

Self-test passed successfully and switch is operational.

 

 

 

Blinking

A nonfatal error occurred during the self-test.

 

 

 

Off

The switch failed the self-test.

RPSU

RPSU status

Green

On

The switch is connected to the HRPSU and can receive

 

 

 

 

power if needed.

 

 

 

Off

The switch is not connected to the HRPSU or HRPSU is

 

 

 

 

not supplying power.

CAS Up

Stack mode

 

Off

The switch is in standalone mode.

 

 

Green

On

The switch is connected to the upstream unit’s Cascade A

 

 

 

 

In connector.

 

 

Amber

On

The Cascade A Out connector (CAS Up) for this switch is

 

 

 

 

looped internally (wrapped to the secondary ring).

(continued)

1-6

302401-D Rev 00

Page 32
Image 32
Nortel Networks manual BayStack 450-12F Switch, Label Type Color State Meaning