BayStack 450 10/100/1000 Series Switches

S1

 

 

 

 

 

 

 

 

VLAN 3

 

 

 

 

 

VLAN 2

VLAN 1

 

Port 2

Port 4

Port 10

Port 8

Port 6

Port 11

PVID = 2

 

 

PVID = 3

PVID = 1

 

V2

V2

V2

V3

V1

V2

Key

VLAN 1 (PVID = 1)

VLAN 2 (PVID = 2)

VLAN 3 (PVID = 3)

BS45019A

Figure 1-25. VLAN Broadcast Domains Within the Switch

For example, to create a broadcast domain for each VLAN shown in Figure 1-25, configure each VLAN with a port membership, and each port with the appropriate PVID/VLAN association:

Ports 8, 6, and 11 are untagged members of VLAN 1.

The PVID/VLAN association for ports 6 and 11 is: PVID = 1.

Ports 2, 4, 10, and 8 are untagged members of VLAN 2.

The PVID/VLAN association for ports 2, 4, and 10 is: PVID = 2.

Ports 2, 4, 10, 8, 6, and 11 are untagged members of VLAN 3. The PVID/VLAN association for port 8 is: PVID = 3.

The following steps show how to use the VLAN configuration screens to configure the VLAN 3 broadcast domain shown in Figure 1-25.

302401-D Rev 00

1-41

Page 67
Image 67
Nortel Networks 450 manual Vlan Broadcast Domains Within the Switch