Reset

The Reset option (accessed from the main menu) allows you to reset a standalone switch, a specific unit in a stack configuration, or an entire stack without erasing any configured switch parameters. Resetting the switch takes approximately 5 seconds. During this time, the switch initiates a self-test that comprises various diagnostic routines and subtests. The LEDs display various patterns to indicate that the subtests are in progress. The results of the self-test are displayed briefly (5 or 10 seconds) in the Self-Test screen (Figure 3-39), which is followed by the Nortel Networks logo screen (Figure 3-40).

Note: The Self-Test screen remains displayed only if the self-test detects a fatal error.

BayStack 450-24T Self-Test

 

CPU RAM test

... Pass

ASIC addressing test

... Pass

ASIC buffer RAM test

... Pass

Port internal loopback test

... Pass

Fan Test

.Pass

Self-test complete.

 

Figure 3-39. Self-Test Screen After Resetting the Switch

Note: The Self-Test screen for a switch that is participating in a stack

configuration includes an additional test: Cascade SRAM test.