BayStack 450 10/100/1000 Series Switches

How the MultiLink Trunk Reacts to Losing Distributed Trunk Members

If your MultiLink Trunk (Figure 1-46) spans separate units in a stack configuration and any of those units (or trunked MDAs) becomes inactive from a loss of power or unit failure, the unaffected trunk members remain operational.

T1

 

Accelar 1150/1150R

 

Routing Switch

CPU PS1 PS2 FAN

(XLR1102SR I/O Modules)

 

BayStack 450-24T Switches

Unit 1

450-1SR MDA

Unit 2

Unit 3

450-1SR MDA

Unit 4

Unit 5

450-1SR MDA

Unit 6

Unit 7

450-1SR MDA

Unit 8

BS45075A

Figure 1-46. Loss of Distributed Trunk Members

However, until you correct the cause of the failure or change the trunk Status field to Disabled, you will be unable to modify any of the following parameters for the affected trunk:

VLAN Configuration

Spanning Tree Configuration

Port Mirroring Configuration

Port Configuration

IGMP Configuration

Rate Limiting Configuration

302401-D Rev 00

1-71

Page 97
Image 97
Nortel Networks 450 manual Loss of Distributed Trunk Members