16.1.1 SMDR (Station Message Detail Recording)

b.Skip Perforation: determines the number of lines to be skipped at the end of every page. 13.1 [11-1]Main—SMDR— SMDR Format—Blank Footer Length (Number of Lines)

[803] SMDR Skip Perforation

The page length should be at least four lines longer than the skip perforation length.

Explanation:

Skip

Perforation

Page

Length

Machine Perforation

SMDR data is not deleted even if the PBX is reset.

If the PBX is reset during a conversation, the call will not be logged by SMDR.

The following calls are regarded as two separated calls in the SMDR:

Calls before and after the flash/recall/EFA signal is manually sent during a conversation

CO-to-CO line calls by Call Transfer, FWD or DISA (each is logged as both an "incoming call" and an "outgoing call")

The PBX waits for a preprogrammed time period after the end of dialing before starting the SMDR timer for outgoing CO line calls. When the PBX has sent out all dialed digits to the telephone company and this timer expires, the PBX begins measuring the duration of the call. A display proprietary telephone (PT) shows the elapsed time of the call. The starting time and the total duration of the call are logged by SMDR.

4.4 [2-3] Timers & Counters—Dial / IRNA / Recall / Tone— Dial—Analog CO Call Duration Start [208] Call Duration Count Starting Time for LCOT

Serial Interface (RS-232C) Parameters

The following communication parameters can be assigned for the Serial Interface (RS-232C port).

a. New Line Code: Select the code appropriate for the PC or printer. If the PC or printer automatically feeds lines with carriage return, select "CR." If not, select "CR+LF."

13.1[11-1]Main—RS-232C—Communication—NL Code

[800] RS-232CParameter—New Line Code

b. Baud Rate: Baud rate indicates the transmission speed of data from the PBX to the PC or printer.

13.1[11-1]Main—RS-232C—Communication—Baud Rate

[800]RS-232CParameter—Baud Rate

c.Word Length: Word length indicates how many bits compose each character.

13.1 [11-1]Main—RS-232C—Communication—Word Length

[800]RS-232CParameter—Word Length

d.Parity Bit: Parity bit indicates what type of parity is used to detect errors in the string of bits composing a character. Make an appropriate selection depending on the requirements of the PC or printer.

13.1 [11-1]Main—RS-232C—Communication—Parity Bit

[800]RS-232CParameter—Parity Bit

e.Stop Bit Length: Stop bit indicates the end of a bit string which composes a character. Select an appropriate value depending on the requirements of the PC or printer.

13.1 [11-1]Main—RS-232C—Communication—Stop Bit

[800]RS-232CParameter—Stop Bit Length

If a call is transferred to an ICD group using Automatic Transfer, the condition code "TR" will not be recorded on SMDR (3.1.8 Call Transfer).

Host PBX Access Code

Document Version 2008-11

Feature Manual

289