test print press feed key
print size

Section 7. Factory Resets

7.4 Clear Dispenser Counter

To reset the printer to the factory settings, perform the following steps.

Caution: Resetting the printer will clear all registers.

STEP

PROCEDURE

1.Record all current dip switch positions, then place all switches in the OFF position.

2.Place the DSW2-4 in the ON or up postion.

3.Press the LINE and FEED key while simultaneously turning ON the power switch. When the printer beeps, release the keys. The following screens will appear.

initializing

 

maintenance mode

rom v00.00.00.00

 

dipsw2-4 on->off

 

 

 

 

4.Place the DSW-4 in the OFF postion and the following screen will appear.

factory mode

5.Press the FEED key to display the next screen.

counter clear none

6.Press the LINE key trice to change the message from NONE to DIS.

counter clear Dis

7.Press the FEED key to clear the DISPENSER Counter. After a pause, the next

screen will appear.

small large

8.Select the print label size by pressing the LINE key. The default is LARGE.

9.Press the FEED key for a test print. Press the FEED key again to stop printing.

Warning: This test activates all the heating elements on the print head and therefore should be used for testing purposes only with full width labels to avoid damaging the print head.

10.Verify that the counters on the test print have reset to 0.0 km.

11.Power OFF the printer and confirm that all switches are in the OFF or down position.

Page 7-4

SATO CL408e/CL412e Service Manual

PN 9001078 Rev. B

Page 132
Image 132
SATO CL412E service manual Counter clear Dis, Clear Dispenser Counter