Section 2. Configuration
2.2 Default Settings
Dip Switch Selections
All switches are placed in the Off position (default) except Receive Buffer for shipping. This will result in the following operating configuration:
Communications: (1) | 8 data bits, no parity, 1 Stop bit, 9600 Baud (1) |
Protocol: (1) | Ready/Busy |
Sensor: | Gap Sensor |
Receive Buffer: | |
Mode: | Batch Continuous |
Label Sensor: | Sensor Used |
Backfeed: | Enabled |
External Signals: | Disabled |
(1) Applicable only if an RS232 Interface Card is installed in the printer.
Software Default Settings - The printer stores any software settings upon receipt from the host and uses them until they are again changed by receipt of a command containing a new setting. These settings are stored in
| CL408e/CL412e |
|
|
Print Darkness | 3 |
|
|
Print Speed | 4 in. per sec. |
|
|
Print Reference | Vertical = 0000, Horizontal = 0000 |
|
|
Zero | Slash |
|
|
Auto | Enabled |
|
|
Once the default operation is completed, a DEFAULT SETTING COMPLETED message will be displayed on the LCD panel and a single "beep" will be heard. The printer should be powered off while this message is being displayed. This saves the default settings in the EEPROM where they will be automatically loaded the next time the printer is powered on.
DEFAULT SETTING
COMPLETED
PN 9001078 | SATO CL408e/CL412e Service Manual | Page |
Rev. B |
|
|