Section 4. Electric Checks and Adjustments

Ribbon Sensor Voltage Checking

ATTACH THE GROUND (BLACK) PROBE FROM THE MULTIMETER TO PIN 4 (GROUND) AND THE SIGNAL (WHITE) PROBE TO PIN 3

TO CHECK VOLTAGE RANGE FOR

RIBBON SENSOR, ROTATE CARBON

UNWIND SPINDLE.

LOW VALUE ~/- 1.6V

HIGH VALUE ~/- 4.8V

PN 9001078

SATO CL408e/CL412e Service Manual