Section 4. Electric Checks and Adjustments

4.7 Eye-Mark Adjustment

Additional equipment required: TP Test Module

Digital Multimeter

STEP PROCEDURE

Refer to Section 4.2 for access to main PCB

1.Turn VR5 (IM) potentiometer on the main PCB all the way to the left.

2.Refer to Section 4.3.

Set the digital multimeter to DC voltage measurement mode. Attach the connector from the TP Test Module to the test port on the main PCB. Note correct positioning of connector. Nibs on the connector are placed down in the receptacle on the PCB in the forward position. Set the dial to 4.

3.Connect (+) probe of the multimeter to Sig+ and (-) probe to pin GND.

4.For Low level (no "Eye-Mark" part) adjustment, put paper part in the sensor. Then adjust the electrical level with VR5 on the main PCB so that it will measure less than 0.5 V

5.For High level ("Eye-Mark" part) adjustment, put paper part with the "Eye-Mark" part in the sensor and check the electrical level. If the level difference is +1.0 V more than the Low level, it is acceptable. If not, return to STEP 4 and readjust VR5.

6.

Standard values:

Low level (no "Eye-Mark" part): +0.5 V or less.

 

 

High level ("Eye-Mark"): Low level +1.0 V or

 

 

higher. If these values do not result, try the

 

 

following:

 

 

a)

Repeat the process

 

 

b)

Clean the sensor

 

 

c)

Verify sensor is operational

 

 

d)

Replace labels with higher quality labels

 

 

e)

Perform factory reset

PN 9001078

SATO CL408e/CL412e Service Manual

Page 4-11