Section 2. Configuration
Dip Switch Settings
RS232 Transmit/Receive Setting (located on RS232 I/F Module)
Data Bit Selection
data bits for each byte transmitted.
DSW1
SETTING | ON |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| |
Off | 8 data bits | OFF |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |
On | 7 data bits |
|
|
|
|
|
|
|
|
|
| |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | |||||
|
|
Parity Selection
SETTING | ||
|
|
|
Off | Off | None |
Off | On | Even |
On | Off | Odd |
On | On | Not Used |
|
|
|
DSW1
ON
OFF
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Stop Bit Selection
|
|
|
|
|
|
|
| DSW1 |
|
|
| ||
SETTING | ON |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
Off | 1 | Stop Bit | OFF |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
On | 2 | Stop Bits |
|
|
|
|
|
|
|
|
|
| |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | ||||||
|
|
|
Baud Rate Selection (DSW1-5, DSW1-6): port.
SETTING | ||
|
|
|
Off | Off | 9600 |
Off | On | 19200 |
On | Off | 38400 |
On | On | 57600 |
|
|
|
Selects the data rate (bps) for the RS232
DSW1
ON
OFF
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Protocol Selection
(* Will select protocol
SETTING | ||
|
|
|
Off | Off | Rdy/Bsy |
Off | On | Xon/Xoff |
On | Off | |
On | On | |
|
|
|
DSW1
ON
OFF
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |