SATO CL412E service manual Standard Operation

Models: CL412E

1 219
Download 219 pages 45.03 Kb
Page 72
Image 72

Section 3. Interface Specifications

NOTE: The signals on pins 1, 3, 4, 6, 9 and 10 each have an open collector output. These pins normally measure +.07V maximum when a true condition exists. If a false condition occurs, the voltage will drop to 0V. To achieve a signal level of +5V, you must add a 330 ohm, ¼ W pull-up resistor between the open collector output pin and Vcc (pin 13) as illustrated. This will provide a signal level of +5V for a true condition and 0V when a false condition exists. The maximum voltage that can be applied to these pins is +50V and the maximum current they can sink is 500 milliamps.

Pin 13

Vcc= +5V

330 ohm, 1/4W

Signal Out

Pin 1, 3, 4, 6, 9 or 10

Standard Operation

Start of Print Cycle

End of Print Cycle

Print Start

+5V

 

Input

0V

 

Print Repeat +5V

Input

0V

 

Print End

+5V

Type 1

0V

 

 

20 Milliseconds

Print End

+5V

 

Type 2

0V

 

Print End

+5V

 

Type 3

0V

 

Print End

+5V

Type 4

0V

 

Page 3-12

SATO CL408e/CL412e Service Manual

PN 9001078 Rev. B

Page 72
Image 72
SATO CL412E service manual Standard Operation