Section 3. Interface Specifications

3.9 Accessory (EXT) Connector

The EXT connector on the rear panel of the CL408e/CL412e printers is intended for use with external printer accessories such as label rewinders or applicators. The 14 pin Centronics type connector provides a choice of four different output signals along with various error conditions. A DB-9 to 14 pin Centronics adapter cable is provided for legacy applications.

Old

DB-9 14 Pin

Centronics

Pin Assignments

PIN

PIN

DIRECTION

SIGNAL DESCRIPTION

 

 

 

 

1

13

To Host

Vcc -/+5V

 

 

 

 

 

 

 

Ribbon Near End - This pin goes high when the amount of ribbon

2

10

To Host

on the unwind shaft is approximately 46 feet (14 m). The output will

 

 

 

be low when the ribbon is completely out.

 

 

 

 

3

4

To Host

Error - This pin goes low when the printer detects an error condition

such as head open or receiving buffer is full.

 

 

 

 

 

 

 

4

7

To Printer

Reprint - A duplicate of the last label in a print job will be reprinted

when this signal is received.

 

 

 

 

 

 

 

 

 

 

Print Start - The printer will print one label when this pin is pulled to

5

5

To Printer

ground. This signal must be enabled by placing switch DSW3-5 on

 

 

 

the Control Panel in the OFF position.

 

 

 

 

 

 

 

End Print - It is used to drive an applicator or other external device

6

6

To Host

requiring synchronization with the print cycle. You may choose

between four types of output signals using control panel DSW3-6

 

 

 

 

 

 

and DSW3-7 selections. See timing charts on next page.

 

 

 

 

7

1

To Host

Label Out - This pin goes low (0V) when a label error exists.

 

 

 

 

8

3

To Host

Ribbon Out - This pin goes low (0V) when ribbon is out.

 

 

 

 

9

2

Reference

Signal Ground

 

 

 

 

 

8

To Printer

Isolated Power Source for signal input.

 

 

 

 

 

 

 

When Mode 1 in LCD selected High Voltage = On-Line Print Job

 

9

To Host

waiting.

 

When Mode 2 in LCD selected High Voltage = On-Line. This goes

 

 

 

 

 

 

low (0V) when printer Off-Line.

 

 

 

 

 

11

 

Reserved

 

 

 

 

 

12

To Host

+24V +/- 10% @2A - Power for external devices

 

 

 

 

 

14

 

Frame Ground

 

 

 

 

PN 9001078