Commissioning (software)
4.6 Using drive-related I/Os by SIMOTION
D410
Commissioning Manual, 08/2008 Edition 105
Table 4-10 Global measuring inputs, configuration of the Measuring Input TO
Axis measuring system no. Under axis measuring system number, enter the number of the used
encoder system (namely, encoder 1, 2 or 3). Encoder system 1 is the
default setting.
Global measuring Activate the checkbox when a global measuring input is used.
Enter here the logical HW address and the bit number of the used
input.
Start address message frame 39x + 3, bit 1 for input DI/DO 9
Start address message frame 39x + 3, bit 2 for input DI/DO 10
Logical hardware address
and bit number:
Start address message frame 39x + 3, bit 3 for input DI/DO 11
Detailed information is contained in the
SIMOTION Motion Control Output Cams and
Measuring Outputs
Function Manual.
4.6.8 Outputs of cam outputs and probe inputs on TM15/TM17 High Feature Quantity framework for TM15/TM17 High Feature
The TM15/TM17 High Feature Terminal Modules can be used to extend the number of
outputs for cam outputs and probe inputs that can be installed.
● TM15, maximum 24 outputs for cam outputs / probe inputs
● TM17 High Feature, maximum 16 outputs for cam outputs / probe inputs
Additional references
Detailed information for the configuration is contained in the following documents
● SIMOTION Output Cams and Measuring Inputs Function Manual
● TM15/TM17 High Feature Terminal Modules Commissioning Manual