Commissioning (software)

4.6 Using drive-related I/Os by SIMOTION

D410
Commissioning Manual, 08/2008 Edition 105
Table 4-10 Global measuring inputs, configuration of the Measuring Input TO
Axis measuring system no. Under axis measuring system number, enter the number of the used
encoder system (namely, encoder 1, 2 or 3). Encoder system 1 is the
default setting.
Global measuring Activate the checkbox when a global measuring input is used.
Enter here the logical HW address and the bit number of the used
input.
Start address message frame 39x + 3, bit 1 for input DI/DO 9
Start address message frame 39x + 3, bit 2 for input DI/DO 10
Logical hardware address
and bit number:
Start address message frame 39x + 3, bit 3 for input DI/DO 11
Detailed information is contained in the

SIMOTION Motion Control Output Cams and

Measuring Outputs

Function Manual.
4.6.8 Outputs of cam outputs and probe inputs on TM15/TM17 High Feature

Quantity framework for TM15/TM17 High Feature

The TM15/TM17 High Feature Terminal Modules can be used to extend the number of
outputs for cam outputs and probe inputs that can be installed.
TM15, maximum 24 outputs for cam outputs / probe inputs
TM17 High Feature, maximum 16 outputs for cam outputs / probe inputs

Additional references

Detailed information for the configuration is contained in the following documents
SIMOTION Output Cams and Measuring Inputs Function Manual
TM15/TM17 High Feature Terminal Modules Commissioning Manual