Siemens D410 appendix Configuring free message frames by means of Bico, Message frames

Models: D410

1 150
Download 150 pages 59.82 Kb
Page 92
Image 92

Commissioning (software)

4.6 Using drive-related I/Os by SIMOTION

4.6.4Configuring free message frames by means of BICO

Overview

For the "free message frame configuring using BICO", dedicated message frames for the data transmission are assigned to the associated drive objects (e.g. terminal modules). Message frame type: Free message frame configuring using BICO (only slaves)

To allow SIMOTION to access the SINAMICS drive signals, e.g. I/Os, they must be interconnected to the SINAMICS using BICO to the message frame. The "free message frame configuring using" is a preferred solution when I/Os are to be divided channel-granular between SIMOTION and SINAMICS and a module view is preferred.

Table 4-4

Drive object: Maximum number of PSDs

 

 

 

 

 

Drive object

 

Maximum number of PSDs for the configuring of the PROFIBUS

 

 

message frames

 

 

 

Input data

Output data

 

 

(from the SIMOTION D

(from the SIMOTION D

 

 

viewpoint)

viewpoint)

TM15 DI/DO

 

5

5

TM31

 

5

5

TM41

 

19

16

Control Unit (CU)

15

5

Free message frame configuring using the TM31 as example

The example describes the interconnection of a signal to the TM31 connected to a

SIMOTION D410.

Steps in configuring user-specific message frames using BICO:

Configure a user-specific message frame

Interconnect the message frame for TM31

Create I/O variables in SIMOTION SCOUT

Prerequisite

You have already created a project and configured a drive.

92

D410

Commissioning Manual, 08/2008 Edition

Page 92
Image 92
Siemens D410 Configuring free message frames by means of Bico, Free message frame configuring using the TM31 as example