Commissioning (software)
4.3 Configuring the system in online mode
Procedure
Now go ahead and adapt your components to suit the application.
Run the wizards for all
This procedure corresponds with the description in chapter "Configuring the system in offline mode".
Note
If only the message frame type needs to be selected for the edit, you can also set this in the "Configuration" screen form of the drive element. A HW Config match is then required.
Configuring the system in offline mode (Page 62)
4.3.5Aligning HW Config
See also
Aligning HW Config (Page 70)
4.3.6Download the project to SIMOTION D410
After having aligned HW Config, download the configuration to SINAMICS Integrated.
1.Save and compile the project.
2.Go online to SIMOTION D410.
3.Select the "Download project to target system" command to download the project to SIMOTION D410. The connection to SINAMICS Integrated is activated automatically.
Drive programming and commissioning is completed. You can now test the drive using the drive control panel.
78 | D410 |
Commissioning Manual, 08/2008 Edition |