Configuring SIMOTION D410

3.3Configuring the PROFIBUS DP interface (only D410 DP)

3.3.2Assignment of the PROFIBUS addresses in HW Config

Assigning PROFIBUS addresses

Assign a PROFIBUS address to all devices before you start networking these in order to enable intercommunication.

Note

All PROFIBUS addresses you assign must be unique on the PROFIBUS subnet.

Information pertaining to the rules of communication on the PROFIBUS subnet is available in the SIMOTION D410 Manual.

Define the PROFIBUS address separately for each device on your programming device / PC in HW Config. Certain PROFIBUS DP slaves are equipped with an address switch.

Note

The PROFIBUS addresses set at the devices using these switches must correspond with the address settings in HW Config.

Recommendation for PROFIBUS addresses

Reserve PROFIBUS address "0" for a service programming device and "1" for a service HMI device which are connected to the subnet as required.

Recommended PROFIBUS address setting for SIMOTION D410 in case of replacement or service:

Reserve address "2" for a SIMOTION D410. This prevents redundancy of the addresses after SIMOTION D410 is installed in the subnet with default settings (for example, when replacing a SIMOTION D410). Assign addresses higher than "2" to any additional devices on the subnet.

D410