FRU

Action

 

 

 

4

System board

Replace the current system board with the original system board.

 

 

See “System board and inner shield removal” on page 4-76.

 

 

If the error remains, go to step 6.

 

 

 

5

Interconnect card assembly

Replace the original interconnect card assembly with a new and not

 

 

previously installed interconnect card assembly. If the problem

 

 

remains, contact the next level of support.

 

 

 

6

System board

Replace the original system board with a new and not previously

 

 

installed system board. If the problem remains, contact the next level

 

 

of support.

 

 

 

Charge roll service check

Service tip: Close and evenly spaced repetitive marks 47.19 mm (1.86 in.) apart, or spots on the page can be caused by a damaged or contaminated dual charge roll.

Service tip: Make sure the right charge roll arm bushing is correctly installed and operates correctly.

To remove the charge roll:

1.Wrap a piece of plain white paper around the charge roll to prevent contamination or damage.

2.Carefully remove the roll by pressing outward and to the right on the charge roll link arm and remove the charge roll from the right side charge roll bearing.

3.Remove the charge roll from the left side charge roll bearing and remove the roll from the printer. Leave the paper wrapped around the charge roll until it is reinstalled.

 

FRU

Action

 

 

 

1

Charge roll assembly

Check the charge roll for correct installation, toner buildup, marks,

 

 

cuts, or other signs of contamination or damage. Replace as

 

 

necessary.

 

 

 

2

Left side charge roll link

Check the left side charge roll link assembly for correct assembly

 

 

operation. Check for damage to the arm or bearing assembly.

 

 

 

3

Right side charge roll link

Check the right side charge roll link assembly for correct assembly

 

Right charge roll bushing

operation. If incorrect, replace the charge roll link assembly with the

 

charge roll link assembly kit. If correct, check the right charge roll link

 

 

 

 

assembly bearing for signs of wear or contamination. Excessive

 

 

contamination could cause intermittent charging of the charge roll. If

 

 

incorrect, replace the link assembly. Check for continuity of the right

 

 

link assembly from the bearing to the charge roll high voltage contact

 

 

on the right side frame. If incorrect, replace the link assembly.

 

 

Make sure the charge roll bushing is installed and operating correctly.

 

 

Note: The screw that attaches the charge roll lead to the contact

 

 

must be secure.

 

 

 

Diagnostic information 2-79

Page 115
Image 115
Toshiba e-STUDIO500P manual Charge roll service check, See System board and inner shield removal on