Signature button contact assembly removal

1.Remove the print cartridge.

2.Remove the left side door. See “Left door removal” on page 4-6.

3.Remove the right cover. See “Right cover removal” on page 4-8.

4.Remove outer system board shield. See “Outer shield removal” on page 4-67.

5.Disconnect signature button cable from connector J14 on the system board.

6.On models 200/210/400/410, remove the two screws (A) securing the blower duct.

7.Remove the signature button contact assembly mounting screw (B).

8.Remove the assembly signature button contact assembly.

Note: Be sure to route the cable in the same location, as shown (C), when replacing the assembly.

Repair information 4-75