Service error codes (9xx.xx) (continued)

Error

Sub

Display text

Description

Action

code

codes

 

 

 

 

 

 

 

 

 

 

923

.01

Fuser over temperature.

Short in the thermistor circuit.

Go to “923.xx—Hot fuser

 

 

Fuser page count

Noisy thermistor signal

service check” on page 2-90.

 

 

between 0 and 99,999.

 

 

 

Fuser is actually overheating due to

 

 

 

 

 

 

 

 

 

hardware faults.

 

 

 

 

 

 

 

923

.11

Fuser over temperature.

Short in the thermistor circuit.

Go to “923.xx—Hot fuser

 

 

Fuser page count

Noisy thermistor signal

service check” on page 2-90.

 

 

between 100,000 and

 

 

 

Fuser is actually overheating due to

 

 

 

199,999.

 

 

 

 

 

hardware faults.

 

 

 

 

 

 

 

923

.21

Fuser over temperature.

Short in the thermistor circuit.

Go to “923.xx—Hot fuser

 

 

Fuser page count

Noisy thermistor signal

service check” on page 2-90.

 

 

between 200,000 and

 

 

 

Fuser is actually overheating due to

 

 

 

299,999.

 

 

 

 

 

hardware faults.

 

 

 

 

 

 

 

923

.31

Fuser over temperature.

Short in the thermistor circuit.

Go to “923.xx—Hot fuser

 

 

Fuser page count

Noisy thermistor signal

service check” on page 2-90.

 

 

between 300,000 and

 

 

 

Fuser is actually overheating due to

 

 

 

399,999.

 

 

 

 

 

hardware faults.

 

 

 

 

 

 

 

923

.41

Fuser over temperature.

Short in the thermistor circuit.

Go to “923.xx—Hot fuser

 

 

Fuser page count

Noisy thermistor signal

service check” on page 2-90.

 

 

between 400,000 and

 

 

 

Fuser is actually overheating due to

 

 

 

499,999.

 

 

 

 

 

hardware faults.

 

 

 

 

 

 

 

923

.51

Fuser over temperature.

Short in the thermistor circuit.

Go to “923.xx—Hot fuser

 

 

Fuser page count

Noisy thermistor signal

service check” on page 2-90.

 

 

stopped at 500,000 to

 

 

 

Fuser is actually overheating due to

 

 

 

preserve data.

 

 

 

 

 

hardware faults.

 

 

 

 

 

 

 

923

.91

Fuser over temperature.

Short in the thermistor circuit.

Go to “923.xx—Hot fuser

 

 

Fuser page count not

Noisy thermistor signal

service check” on page 2-90.

 

 

available.

 

 

 

Fuser is actually overheating due to

 

 

 

 

 

 

 

 

 

hardware faults.

 

 

 

 

 

 

 

924

.01

Open thermistor check

Noisy thermistor signal.

Go to “924.xx—Hot fuser

 

 

failure. Fuser page

Intermittent connection.

service check” on page 2-91.

 

 

count between 0 and

 

 

 

Thermistor cable not connected or

 

 

 

99,999.

 

 

 

 

 

thermistor actually open.

 

 

 

 

 

 

 

924

.11

Open thermistor check

Noisy thermistor signal.

Go to “924.xx—Hot fuser

 

 

failure. Fuser page

Intermittent connection.

service check” on page 2-91.

 

 

count between 100,000

 

 

 

Thermistor cable not connected or

 

 

 

and 199,999.

 

 

 

 

 

thermistor actually open.

 

 

 

 

 

 

 

924

.21

Open thermistor check

Noisy thermistor signal.

Go to “924.xx—Hot fuser

 

 

failure. Fuser page

Intermittent connection.

service check” on page 2-91.

 

 

count between 200,000

 

 

 

Thermistor cable not connected or

 

 

 

and 299,999.

 

 

 

 

 

thermistor actually open.

 

 

 

 

 

 

 

924

.31

Open thermistor check

Noisy thermistor signal.

Go to “924.xx—Hot fuser

 

 

failure. Fuser page

Intermittent connection.

service check” on page 2-91.

 

 

count between 300,000

 

 

 

Thermistor cable not connected or

 

 

 

and 399,999.

 

 

 

 

 

thermistor actually open.

 

 

 

 

 

 

 

 

 

 

 

 