922.xx—Cold fuser check

Error codes 920.xx and 922.xx may display for a cold fuser failure.

Some 920.xx error codes may be cleared by turning the printer on and off and allowing it to complete POR.

CAUTION: There is a danger from hazardous voltage in the area of the printer where you are working. Unplug the printer before you begin, or use caution if the printer must receive power in order to perform the task.

Service tip: Set the Fuser Temperature to NORMAL before starting this service check. In Diagnostics mode,

select EP SETUP, and Fuser Temp.

 

FRU

Action

 

 

 

1

Fuser lamp

Remove the fuser assembly and check to make sure the correct fuser

 

 

lamp has been installed. If the correct lamp has been installed, go to

 

 

step 2.

 

 

Note: If the fuser lamp is replaced, allow the fuser assembly to cool

 

 

or a 925.xx error code could be displayed.

 

 

 

2

AC line voltage

CAUTION: When taking measurements for AC power, observe all

 

 

safety precautions.

 

 

Check the AC line voltage to make sure it is within operating

 

 

specification. If incorrect, inform the customer; if correct, go to step 3.

 

 

 

3

LVPS

CAUTION: When taking measurements for AC power, observe all

 

 

safety precautions.

 

 

Unplug the AC line cord from the printer and pull the LVPS out far

 

 

enough to access CN1 on the LVPS board (see “Low voltage power

 

 

supply removal” on page 4-54). Disconnect the LVPS to fuser AC

 

 

cable, plug in the line cord, turn the printer on and measure the

 

 

voltage between CN1-1 and CN1-3 on the connector (see the

 

 

connector locations at “Low voltage power supply removal” on

 

 

page 4-54).

 

 

If incorrect, replace the LVPS assembly (see “Low voltage power

 

 

supply removal” on page 4-54); if correct, go to step 4.

 

 

 

4

LVPS

CAUTION: When taking measurements for AC power, observe all

 

LVPS fuser AC cable

safety precautions.

 

Disconnect the AC line cord from the printer. Disconnect the LVPS to

 

 

 

 

fuser cable from the fuser to fuser lamp cable. Plug the AC line cord

 

 

into the printer and check the AC line voltage between the pins on the

 

 

fuser end of the LVPS to fuser AC cable. If the voltage is correct,

 

 

unplug the AC power cord from the LVPS cable and pull the LVPS out

 

 

far enough to be able to check the voltage between CN-1 and CN-3

 

 

on the LVPS board. Plug in the power cord, turn the printer on and

 

 

check the voltage. If correct, replace the LVPS to fuser AC cable; if

 

 

incorrect, replace the LVPS assembly. See “Low voltage power

 

 

supply removal” on page 4-54.

 

 

Note: If the fuses in the LVPS are blown, the LVPS assembly must be

 

 

replaced.

 

 

 

5

Fuser top cover assembly

Check to make sure that the thermistor is installed correctly to J5 on

 

(thermistor, thermistor

the fuser control card. If installed correctly check the cable for any

 

cable)

signs of damage. If any problems are found, replace the fuser top

 

Fuser to system board DC

cover assembly.“Fuser narrow media sensor removal” on

 

page 4-34.

 

cable

 

If no problem is found, check the fuser to system board DC cable for

 

 

 

 

correct installation at J1 on the fuser control card. If no problem is

 

 

found, check the fuser to system board cable for correct installation at

 

 

J10 on the system board. If no problem is found, go to step 6.

 

 

 

Diagnostic information 2-89

Page 125
Image 125
Toshiba e-STUDIO500P manual Xx-Cold fuser check, Connector locations at Low voltage power supply removal on