The elevator tray does not move up or down; the printer recognizes that the option is installed

 

FRU

Action

 

 

 

1

DC drive motor high-

Be sure the motor cable is correctly installed at J1 on the board.

 

capacity feeder option

Check the cables, damaged or loose wires. Disconnect the motor.

 

system board

Check for a short between each pin and the motor housing. If a

 

 

problem is found, replace the motor assembly. If no problem is found,

 

 

measure the resistance between the following pins on the motor

 

 

cable connector:

 

 

Pins 1 (brown) and pin 2 (Yellow)

 

 

The resistance measures between approximately 7.5 and 10.5 ohms.

 

 

If incorrect, replace the motor assembly. If correct, replace the high-

 

 

capacity feeder option system board.

 

 

 

The elevator moves in one direction only

 

FRU

Action

 

 

 

 

 

 

 

 

 

 

1

DC drive motor assembly

Check the voltages at J1 on the high-capacity system board. The

 

high-capacity feeder

voltages measure approximately as follows:

 

system board

 

 

 

 

 

 

 

Pin

Color

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Static (motor not running)

 

 

 

 

 

 

 

 

 

 

 

J1-1

Brown

0 V dc

 

 

 

 

 

 

 

 

 

 

 

J1-2

Yellow

0 V dc

 

 

 

 

 

 

 

 

 

 

 

Motor running forward

 

 

 

 

 

 

 

 

 

 

 

J1-1

Brown

0 V dc

 

 

 

 

 

 

 

 

 

 

 

J1-2

Yellow

+24 V dc

 

 

 

 

 

 

 

 

 

 

 

Motor running in reverse

 

 

 

 

 

 

 

 

 

 

 

J1-1

Brown

+24 V dc

 

 

 

 

 

 

 

 

 

 

 

J1-2

Yellow

0 V dc

 

 

 

 

 

 

 

 

 

 

If any of the voltages are incorrect, disconnect the motor and

 

 

measure the resistance between J-1 and J-2. The resistance

 

 

measures between 7.5 and 10.5 ohms. If incorrect, replace the

 

 

motor. If correct, replace the system board.

 

 

 

 

 

 

 

2-98Service Manual

Page 134
Image 134
Toshiba e-STUDIO500P manual Elevator moves in one direction only