High-capacity feeder input tray service check

Note: Voltage measurements in the high-capacity feeder input tray service checks must be made with the high- capacity feeder attached to the base printer to obtain accurate results.

Service tip: Be sure the paper size switch is set to the correct paper size setting and the rear paper guides are in the correct locations for the size of paper installed in the high-capacity feeder tray.

Service tip: Check the other paper sources to be sure they are operating correctly.

The base printer indicates a dead machine condition when the high-capacity input tray is installed

 

FRU

Action

 

 

 

1

AC line cord

If the base printer works normally using the AC line cord from the AC

 

AC jumper (HCIT to printer)

wall outlet and does not work when using the AC jumper from the

 

AC input and output

HCIT, check the AC jumper cord. If defective, replace the cord. If not

 

receptacles

defective, check the AC input and output receptacles and wiring

 

AC wiring harness

harness in the HCIT. Repair or replace the receptacles or AC wiring

 

 

harness as required.

 

 

Note: Make sure the ground wire is installed correctly from the AC

 

 

wiring harness to the frame of the HCIT and the nut and lock washer

 

 

are tightened.

 

 

 

The base printer does not recognize that the high-capacity input tray is installed

 

FRU

Action

 

 

 

1

high-capacity feeder

Check the high-capacity feeder input tray to make sure it is mounted

 

autoconnect mechanical

correctly and is not pushed down into the frame assembly or

 

check

damaged. Be sure the high-capacity feeder input tray autoconnect is

 

 

properly connected to the high-capacity feeder tray option board

 

 

assembly.

 

 

 

2

Base printer or option

Check the option or base printer autoconnect for signs of damage.

 

mounted above

Repair the high-capacity option autoconnect as necessary.

 

 

 

3

LVPS

Check the voltages at J11-2 and J11-4. The voltage measures

 

Option system board

+24 V dc, If the voltage is correct, replace the high-capacity system

 

 

board assembly. If the voltage is incorrect, check the continuity of the

 

 

AC input cable to the LVPS. If correct, replace the LVPS assembly. If

 

 

incorrect, replace the AC cable to the input of the LVPS.

 

 

 

Diagnostic information 2-95