Ready—Binx Full displays and paper feeds into bin x

 

FRU

Action

 

 

 

1

Bin x sensor

Check the sensor flag for binds. Make sure the sensor flag is not in

 

Bin x sensor control board

an up position. If the sensor flag is operating correctly, replace the bin

 

 

x sensor. If this does not fix the problem, replace the control board.

 

 

 

271.xx Paper Jam - Check Bin 1 displays—paper does not feed into the bin selected

 

FRU

Action

 

 

 

1

Deflector

Check all the bin parts for missing or loose springs, binds in the

 

Deflector spring

deflector or deflector cover, broken or binding shaft assemblies, or

 

broken gear teeth. If incorrect, repair as necessary.

 

Deflector cover

 

 

 

Deflector cover spring

 

 

Shaft assemblies

 

 

 

 

2

Bin x solenoid assembly

Check the solenoid for any binds. Make sure the solenoid is

 

Control board

contacting the latch correctly. If incorrect, repair as necessary. If the

 

 

solenoid appears to be operating mechanically, check the resistance

 

 

of the solenoid. It measures between 30 and 50 ohms. If incorrect,

 

 

replace the failing solenoid assembly. If correct, replace the control

 

 

board.

 

 

 

3

Mechanical linkage

If the DC motor is functioning properly, check the gears, clutch, and

 

Motor assembly

other linkage parts for correct operation and wear, broken gear teeth,

 

or damaged parts. If incorrect, replace the mechanical linkage

 

 

 

 

assembly/DC motor assembly.

 

 

 

990.xx Service Error displays

 

 

 

FRU

Action

 

 

 

 

 

 

 

 

 

 

1

Mechanical linkage

Check the DC motor cable connector to be sure it is correctly

 

 

DC motor assembly

installed at J2 on the control board. If correct, disconnect J2 from the

 

 

control board and check the resistance of the motor on the cable

 

 

 

 

 

 

connector. J2-1 to J2-2 measures between 115 and 135 ohms. Also

 

 

 

check J2-1 and J2-4 to the motor case for shorts. If either the

 

 

 

resistance is incorrect or a short is found, replace the mechanical

 

 

 

linkage/DC motor assembly.

 

 

 

Note: If the DC motor is shorted, it may also be necessary to replace

 

 

 

the control board.

 

 

 

 

 

 

 

 

2

Control board

Disconnect the motor cable J2 from the control board and check the

 

 

 

voltages at J2 on the board.

 

 

 

Warning: Use caution not to short adjacent pins on the connector as

 

 

 

damage to the board could result.

 

 

 

 

 

 

 

 

 

 

 

Pin

Measured (motor idle)

 

 

 

 

 

 

 

 

 

 

 

 

J2-1

+24 V dc

 

 

 

 

 

 

 

 

 

 

 

 

J2-2

+24 V dc

 

 

 

 

 

 

 

 

 

 

 

 

J2-5

+5 V dc

 

 

 

 

 

 

 

 

 

 

 

 

J2-6

+5 V dc

 

 

 

 

 

 

 

 

 

 

 

If any of the voltages are incorrect, replace the control board. If

 

 

 

correct, replace the mechanical linkage/ DC motor assembly.

 

 

 

 

 

 

 