OUTPUT BIN TESTS

Feed Tests (output bins)

Use these tests to verify that media can be fed to a specific output bin. Media is fed from the default input source to the selected output bin. No information is printed on the media fed to the output bin because the printhead is not engaged during this test. These tests can use any media size or envelope supported by the printer.

Note: If the Configure Bins printer setting is Link rather than Mailbox, the printer selects its own internal bin linking regardless of which output bin is selected for the feed test.

To run the Feed Tests for the output bins:

1.Select Feed Tests from the OUTPUT BIN TESTS.

2.Select the output bin you want the paper to exit into. The standard bin as well as any output option bin installed on the printer is shown on the menu. (The output bins are displayed in the order installed on the printer.)

3.Select either Single or Continuous.

Single—feeds one sheet of media from the selected source.

Continuous—media continues feeding from the selected source until Stop ( ) is pressed.

Press Back () to return to OUTPUT BIN TESTS.

Feed To All Bins

This test can be used to verify that the printer can feed media to the standard bin or any installed output options. No information will be printed on the test pages, as the printhead is not engaged during the feed test. The media feeds from the default paper source.

To run the Feed To All Bins Test:

Select Feed To All Bins from OUTPUT BIN TESTS.

The printer feeds a separate piece of media to the standard bin first, then it feeds a separate piece of media to each output bin installed in the following order:

Order sheets

Output bins

 

Order sheets

Output bins

 

Order sheets

Output bins

are fed

 

are fed

 

are fed

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Standard bin

 

9

Bin #8

 

17

Bin #5

 

 

 

 

 

 

 

 

2

Bin #1

 

10

Bin #9,

 

18

Bin #4

 

 

 

 

 

 

 

 

3

Bin #2

 

11

Bin #10

 

19

Bin #3

 

 

 

 

 

 

 

 

4

Bin #3

 

12

Bin #10

 

20

Bin #2

 

 

 

 

 

 

 

 

5

Bin #4

 

13

Bin #9

 

21

Bin #1

 

 

 

 

 

 

 

 

6

Bin #5

 

14

Bin #8

 

22

Standard bin

 

 

 

 

 

 

 

 

7

Bin #6

 

15

Bin #7

 

 

 

 

 

 

 

 

 

 

 

8

Bin #7

 

16

Bin #6

 

 

 

 

 

 

 

 

 

 

 

The test is continuous until Stop () is pressed.

Press Back () to return to OUTPUT BIN TESTS.