Fuser exit sensor flag and spring removal

1.Remove the fuser exit sensor. See “Fuser exit sensor removal” on page 4-28.

2.Note the position of the spring (A) in relation to the flag (B).

3.Carefully ease the right arm (C) until the fuser exit sensor cover releases the flag and spring.

Spring replacement

1.Place the spring on the left pin (A).

2.Set the tang (B) on the flag.

4-30Service Manual