FRU

Action

 

 

 

 

 

 

 

 

 

 

 

3

+5 V dc test point on the

Check for approximately +5 V dc at the +5 V test point on the system

 

system board

board.

 

 

Note: Use care not to short adjacent voltage test points.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the voltage is correct, replace the system board assembly. If the

 

 

voltage is incorrect, go to step 4.

 

 

 

4

System board

Check to make sure the LVPS cable is correctly installed at J27 on

 

 

the system board. If not, reseat and recheck the voltage at the

 

 

+5 V dc test point on the system board.

 

 

If test point does not measure +5 V dc, go to step 5.

 

 

 

5

LVPS

Unplug the AC line cord from the LVPS and disconnect the LVPS

 

 

cable to the system board. Reconnect the AC line cord and measure

 

 

the voltage on CN2-1 on the LVPS. The voltage should measure

 

 

approximately +5 V dc.

If the voltage is correct, go to step 6. If the voltage is incorrect, replace the LVPS assembly. See “Low voltage power supply removal” on page 4-54

6Features or option installed Warning: Observe all the ESD precautions and turn the printer off

 

on the interconnect card

before any feature or option cards are removed or replaced.

 

assembly

Remove one option/feature at a time to help isolate the failing part.

 

 

 

 

Replace the faulty part.

 

 

 

7

LVPS fuse F1 (primary

Unplug the AC line cord, remove the LVPS from the printer, and

 

power)

check the continuity of fuse F1. See “Low voltage power supply

 

 

removal” on page 4-54.

 

 

If continuity is correct, replace the LVPS assembly.

 

 

If the voltage is incorrect, replace the LVPS assembly.

 

 

 

8

Loads connected to the

Turn the printer off and disconnect each cable connected to the

 

system board

system board and each option installed on the system board until the

 

 

problem is located.

 

 

Warning: When removing any card installed on the system board

 

 

observe all ESD precautions when handling these options.

Diagnostic information 2-81

Page 117
Image 117
Toshiba e-STUDIO500P manual Voltage on CN2-1 on the LVPS. The voltage should measure