Schneider Electric 58 TRX manuals
Computer Equipment > Computer Drive
When we buy new device such as Schneider Electric 58 TRX we often through away most of the documentation but the warranty.
Very often issues with Schneider Electric 58 TRX begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Computer Drive Schneider Electric 58 TRX is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Computer Drive on our side using links below.
Schneider Electric 58 TRX Manual
232 pages 5.07 Mb
ALTIVAR 58 TRXAC DRIVESFile 8806 / 8839 / 8998 31 ~32 Communication Options33 Ventilation Kits and Conduit Entry KitsVENTILATION KITS CONDUIT ENTRY KITSVentilation Kit for Catalog Number Catalog Number For Drive Controllers 230 Vac 460 Vac Ventilation Kits 34 DYNAMIC BRAKING RESISTOR KITS38 EMC Kits and RFI FiltersELECTROMAGNETIC COMPATIBILITY (EMC) KITS INTERNAL RFI FILTERS EXTERNAL RFI FILTERS 39 Line Reactors and Output FiltersLINE REACTORS MOTOR PROTECTING OUTPUT FILTERS 40 Macro-Configuration ProgrammingMACRO-CONFIGURATION PROGRAMMING DRIVE CONTROLLER IDENTIFICATION SCREEN: INCREASING POWER RATING FOR VARIABLE TORQUE APPLICATIONS 41 Display ParametersDISPLAY PARAMETERSThe following parameters can also be viewed from the Displ ay Menu. Parameter STATUS Description Parameter Units Description 42 Adjustment ParametersADJUSTMENT PARAMETERSNormal Mode Pedestal Mode Deadband Mode Acceleration Deceleration Low Speed and High Speed Diagram 43 Adjustment Parameters49 Drive Control Parameters50 Configurable I/O FunctionsCONFIGURABLE I/O FUNCTIONS 51 Configurable I/O FunctionsLI6 LO AO A+ A LI6 LO AO AI3 LI5 Possible Assignments Assignable I/O on the ATV58 TRX Controller LI3 LI4 R2 AO LI5 B+ B 52 Function Compatibility58 Altivar 58 TRX AC Drives58 The following figure shows a diagram of the PI Regulator inputs, calculation points, and outputs. The following table provides a description of th e inputs to the PI Regulator. 60 Assignment of Analog Inputs (AIx) With Analog I/O Extension CardASSIGNMENT OF ANALOG INPUTS (AIx) WITH ANALOG I/O EXTENSION CARD 61 Assignment of Logic Outputs (R2 or LOx)ASSIGNMENT OF LOGIC OUTPUTS (R2 OR LOx) 63 Assignment of Analog Outputs (AOx)ASSIGNMENT OF ANALOG OUTPUTS (AOx) 64 Assignment of Analog Outputs (AOx)68 Additional Functionality Provided in the ATV58 Type FVC DriveADDITIONAL FUNCTIONALITY PROVIDED IN THE ATV58 TYPE FVC DRIVE 69 ATV58 TYPE FVC ADJUSTMENT PARAMETERS Ability to Shape Acceleration and Deceleration Ramps + Speed/ - Speed with Single Action Pushbuttons and No Reference Saving: Str = SRE 72 Type FVC Analog InputsATV58 TYPE FVC ANALOG INPUTS 73 Type FVC Analog and Logic OutputsATV58 TYPE FVC ANALOG OUTPUTS ATV58 TYPE FVC LOGIC OUTPUTS 74 Parameter Summary74 PARAMETER SUMMARYCode Fact. Setting Cust. Setting Code Fact. Setting Cust. Setting Drive Menu ParametersCode Factory Setting Customer Setting Code Factory Setting Customer Setting Command Menu ParametersCode Factory Setting Customer Setting Code Factory Setting Custom er Setting 75 Parameter SummaryNOTE:Shaded rows indicate I/O available on extension cards. Fault Menu Parameters I/O Assignment 76 Menu OverviewMENU OVERVIEWMenu 1 DISPLAY Menu Menu 2 ADJUST Menu* Requires addition of I/O option card VW3A58201U (analog) or VW3A58202U (digital) Menu 3 DRIVE Menu Menu 4 CONTROL Menu 77 Menu Overview95 Performance Information (Constant Torque Rated Products)PERFORMANCE INFORMATION (CONSTANT TORQUE RATED PRODUCTS) 96 Speed Regulation (Constant Torque Rated Products)SPEED REGULATION (CONSTANT TORQUE RATED PRODUCTS) 97 INSTALLATION RECOMMENDATIONSRemoving the Protective Cover Minimum Clearances 100 WIRING RECOMMENDATIONS101 Ratings for Input Line Currents, Type H Constant Torque 208/230 VacSwitching Frequency: ATV58HU29M2 to D23M2 at 4kHz, ATV58HD28M2 to D46M2 at 2 kHz 102 Ratings for Input Line Currents, Type H Variable Torque 208/230 VacSwitching Frequency: ATV58HU29M2 to D23M2 at 4 kHz, ATV58HD28M2 to D46M2 at 2 kHz Ratings for Input Line Currents, Type H Variable Torque Low Noise 208/230 Vac Switching Frequency: ATV58HU29M2 to D23M2 at 8 kHz, ATV58HD28M2 to D46M2 at 4 kHz 103 Ratings for Input Line Currents, Type H and Type FVC Constant Torque 400/460 VacSwitching Frequency: ATV58U18N4 to D46N4 at 4 kHz, ATV58D54N4 to D79N4 at 2 kHz Ratings for Input Line Currents, Type H Variable Torque Low Noise 400/460 Vac Switching Frequency: ATV58HU18N4 to D46N4 at 8 kHz, ATV58HD54N4 to D79N4 at 4 kHz 104 Ratings for Input Line Currents, Type H Variable Torque 400/460 Vac105 Ratings for Input Line Currents, Types E and F 200 Vac -10% / 240 Vac +10%Ratings for Input Line Currents, Types E and F 400 Vac -15% / 460 Vac +20% V 107 Wiring Diagram for Output Contactor 3 Phase U KM2 KM2 ATV58H LC1- ATV58H LC1-WU1 W1 V1 R2A KM2 R2C KM2 TS 120 VAC TS = Transient suppressor Wiring Diagrams for ATV58 TRX Type H and Type N Controllers 108 +- + - 112 M115 ATV58 TRX TYPE H SPECIFICATIONS118 Type FVC SpecificationsATV58 TYPE FVC SPECIFICATIONSNOTE:Discoloration of drive controller plastic pieces will occur if exposed to direct sunlight. Environmental Specifications Electrical Specifications 119 Type FVC SpecificationsElectrical Specifications (Continued) 120 DIMENSIONSATV58 TRX Type H and Type FVC Models Dimensions for Type H and Type FVC Frame Sizes 1 to 5 Dimensions for Type H and Type FVC Frame Sizes 6 and 7 121 ATV5 8 TRX Type H (continued)Product Frame Size Catalog No. in. (mm) Weig ht in. (mm) in. (mm) K in. (mm) H in. (mm) G in. (mm) F in. (mm) E in. (mm) C in. (mm) B ATV58H A lb (kg) Frame Size 10 Dimensions Frame Size 8 Dimensions Frame Size 9 Dimensions 122 ATV58 TRX Type E and Type F ModelsATV58 TRX Type N Models Dimensions for Type N Models Dimensions for Type E and Type F Models Conduit Entry Kit (VW3A58842 to VW3A58845) 123 bdH= = 126 Weights144 General InformationINTRODUCTION ENCLOSURE TYPES 145 General Information160 Three Phase Line Reactors161 Motor Protecting Output Filters162 Three Phase Drive Isolation Transformers167 GB F168 125500 hp VT Controllers @ 460 V with Integrated or Barriered Bypass (Front and Side Views) 168 Bhp Weight Enclosure Dimensions Enclosure Size 460 V A B VT lb kg in. mm in. mm Dimensions: in. (mm) 125500 hp VT Controllers @ 460 V with Integrated or Barriered Bypass (Conduit Views) 169 F GBarriered Bypass Conduit Entry - Bottom View Integrated Bypass Conduit Entry - Bottom Viewhp 460 V VT Enclosure Dimensions Weight lb kg C in. mm D in. mm E in. mm F in. mm G in. mm Enclosure Size Integrated Bypass Conduit Entry - Top View Barriered Bypass Conduit Entry - Top View Anchor Mounting Holes NOTE: Use 1/2 in. or 3/4 in. diameter grade 5 bolts to secure the floor-mounted structure. 174 Specifications for Drive Controllers (Continued)175 ENCLOSED ADJUSTABLE FREQUENCY DRIVES (1 TO 500 HP)PART 1 GENERAL 176 PART 2 PRODUCT183 PART 3 EXECUTION186 DRIVE SELECTION Product Horsepower Enclosure Type Voltage Rating Application Type Device Type Misc. Options Light Option Control Option 187 Standard Features197 Technical CharacteristicsTECHNICAL CHARACTERISTICSSpecifications for 460 Vac Drive Controllers 198 Dissipated Watts LossDISSIPATED WATTS LOSSTotal Dissipated Watts Loss for Econoflex 230 Vac Controllers Total Dissipated Watts Loss for Econoflex 208 Vac Controllers 199 Dimensions and WeightsDIMENSIONS AND WEIGHTS FOR TYPE 1 AND TYPE 12K ENCLOSURESMounting Information for 1 to 20 HP 460 Vac and 1 to 10 HP 208/230 Vac Controllers Knockout Dimensions 200 Dimensions and Weights200 DIMENSIONS AND WEIGHTS FOR TYPE 1 AND TYPE 12K ENCLOSURES (CONTINUED)Mounting Information for 25 to 100 HP 460 Vac and 15 to 50 HP 208/230 Vac Controllers Knockout Dimensions 201 Recommended Spare PartsRECOMMENDED SPARE PARTS 460 Vac Econoflex ModelsDescription Qty 1 to 7.5 HP Qty 10 to 20 HP Qty 25 to 50 HP Qty 60 to 100 HP 208/230 Vac Econoflex ModelsDescription Qty 1 to 5 HP Qty 7.5 to 10 HP Qty 15 to 25 HP Qty 30 to 50 HP 202 Circuit Breaker List212 General Information and MCC Package FeaturesGENERAL INFORMATION MCC PACKAGE FEATURES 213 Factory Options, Monitoring and IndicationFACTORY OPTIONS MONITORING AND INDICATION 214 AC Drive Options and Basic Drive Power CircuitAC DRIVE OPTIONS BASIC DRIVE POWER CIRCUIT 215 Space RequirementsSPACE REQUIREMENTSVariable Torque 208/240 Vac Altivar 58 TRX AC Drives Constant Torque 480 Vac Altivar 58 TRX AC Drives 216 Space RequirementsConstant Torque 208/240 Vac Altivar 58 TRX AC Drives Variable Torque, Low Noise 480 Vac Altivar 58 TRX AC Drives Variable Torque, Low Noise 208/240 Vac Altivar 58 TRX AC Drives 217 Power Contactor OptionsPOWER CONTACTOR OPTIONSOnly one option is allowed.Power Circu it Diagram Nominal Motor Horsepower (hp) and Type of Torque Integrated Bypass Only Available with Circuit Breaker Disconnect; Uses Telemecanique Contactors. Barriered Bypass Uses NEMA Contactors Barriered Application Rated COMPAC 6 Bypass (14 A max.) CB CB CBor Disc orDisc Separate Bypass Unit CB or Disc 218 Pilot Devices and Misc. Options218 PILOT DEVICES MISCELLANEOUS OPTIONS(5 maximum available) Pilot Lights (Available as LED type, direct supply only.) Option 219 Pilot Devices and Misc. Options220 Multi-Drive Process Line CabinetsMULTI-DRIVE PROCESS LINE CABINETS 221 Wiring DiagramsWIRING DIAGRAMSTypical Wiring Diagram for MCC Altivar 58 TRX AC Drive with Basic Power Option 222 Wiring DiagramsTypical Wiring Diagram for MCC Altivar 58 TRX AC Drive with Barriered Bypass Power Option
Also you can find more Schneider Electric manuals or manuals for other Computer Equipment.