Altivar® 58 TRX AC Drives

Type N Drive Controllers

ATV58NEMA4Xb_w no back.tif

ATV58 TRX Type N Product Family

ATV58 TRX TYPE N DRIVE CONTROLLERS

The ATV58 TRX family of adjustable-frequency AC drive controllers is used to control three-phase asynchronous motors.The ATV58 TRX Type N models contain an ATV58 TRX Type H drive controller packaged in a Type 4/4x stainless steel enclosure. They are for use in food and beverage wash-down applications. The Type N drive controller was tested for corrosion resistance per UL-50 and exceeds this standard. The UL-50 corrosion test was conducted using ASTM B117-1985.

The following models are available:

1 to 10 hp (0.75 to 7.5 kW), 400/460 Vac, 3-phase input.

½ to 3 hp (0.37 to 2.2 kW), 208/230 Vac, single-phase input.

½ to 5 hp (0.37 to 4.0 kW), 208/230 Vac, 3-phase input.

Each Type N drive controller is furnished with four conduit openings that are closed with Type 4/4x plugs. The drive is available with a keypad mounted behind a transparent boot to allow viewing and operation of the keypad while maintaining the Type 4/4x rating. If a keypad is not required, a closing plate can be installed to maintain the Type 4/4x rating. All ATV58 TRX communication and I/O options can be used in the Type N controllers. The Type N drive controllers can be used on constant or variable torque applications. The ratings are shown in the tables below.

208 to 230 Vac, Single-Phase Input with 3-Phase Output

Frame

Drive Controller

Motor Power

Rated Output

Transient Output

 

Current

Current

Size

Catalog Number

 

 

 

 

 

kW

HP

 

A

A

 

 

 

 

 

 

 

 

 

 

1

ATV58NU09M2•

0.37

0.5

 

2.3

3.1

 

 

 

 

 

 

 

1

ATV58NU18M2•

0.75

1

 

4.1

5.6

 

 

 

 

 

 

 

2

ATV58NU29M2•

1.5

2

 

7.8

10.6

 

 

 

 

 

 

 

2

ATV58NU41M2•

2.2

3

 

11

15

208 to 230 Vac, 3-Phase Input with 3-Phase Output

 

 

 

 

 

 

 

 

Frame

Drive Controller

Motor Power

Rated Output

Transient Output

 

Current

Current

Size

Catalog Number

 

 

 

 

 

kW

HP

 

A

A

 

 

 

 

 

 

 

 

 

 

2

ATV58NU29M2•

1.5

2

 

7.8

10.6

 

 

 

 

 

 

 

2

ATV58NU41M2•

2.2

3

 

11

15

 

 

 

 

 

 

 

3

ATV58NU54M2•

3

 

13.7

18.6

 

 

 

 

 

 

 

3

ATV58NU72M2•

4

5

 

18.2

24.7

 

 

 

 

 

 

400 to 460 Vac, 3-Phase Input with 3-Phase Output

 

 

 

 

 

 

Frame

Drive Controller

Motor Power

Rated

Transient Output

 

 

 

Output Current

Current

Size

Catalog Number

 

 

 

 

 

kW

HP

 

A

A

 

 

 

 

 

 

 

 

 

 

2

ATV58NU18N4•

0.75

1

 

2.3

3.1

 

 

 

 

 

 

 

2

ATV58NU29N4•

1.5

2

 

4.1

5.6

 

 

 

 

 

 

 

2

ATV58NU41N4•

2.2

3

 

5.8

7.9

 

 

 

 

 

 

 

3

ATV58NU54N4•

3

 

7.8

10.6

 

 

 

 

 

 

 

3

ATV58NU72N4•

4

5

 

10.5

14.3

 

 

 

 

 

 

 

3

ATV58NU90N4•

5.5

7.5

 

13

17.7

 

 

 

 

 

 

 

4

ATV58ND12N4•

7.5

10

 

17.6

24

 

 

 

 

 

 

 

Complete the catalog number by entering KU for ATV58 Type N drive controllers with factory-installed keypad, or ZU for controllers without a factory-installed keypad. For dimensions, see page 122; for wiring diagrams, see page 108.

Power indicated is for a switching frequency between 0.5 and 4 kHz, and at steady state. For switching frequency between 8 and 16 kHz, derate the drive controller by one horsepower size (for example, for ½ hp,

order drive controller ATV58NU18M2). If the duty cycle (i.e., drive controller run time) does not exceed 60% (36 second maximum for a 60 second cycle), derating is not required for operation above 8 kHz.

For 60 seconds.

When these drive controllers are used with a single-phase input, a line reactor (3% minimum) must be used.

14

© 2000–2003 Schneider Electric All Rights Reserved

 

09/2003

 

 

 

 

Page 14
Image 14
Schneider Electric ATV58 TRX Type N Drive Controllers, Rated Output Transient Output Current Size Catalog Number