Altivar® 58 TRX AC Drives

Summary of User Interface Options and I/O Extension Cards

IO_cards.tif

SUMMARY OF USER INTERFACE OPTIONS

The following table lists the various user interface options and provides a catalog number for ordering.

User Interface Option

Description

Catalog Number

 

 

 

Keypad Display

This plug-in terminal is inserted into a slot on the front panel of the ATV58 TRX controller.

VW3A58101U

 

 

 

Kit for Remote Location of

This kit may be used to locate the keypad display remotely (for example, on the door of the

 

enclosure). The kit includes a 3-meter (9.8 foot) cable with connectors; a translucent protective

VW3A58103

Keypad Display

cover for the keypad; and seals and screws for IP65 mounting on an enclosure door.

 

 

 

 

 

 

PowerSuite Software

PowerSuite commissioning software on CD

VW3A8104

 

 

 

 

Includes the following to connect a PC to an ATV11, ATV28, ATV58, or ATS48 controller:

 

 

1 m cable with RJ45 connectors

VW3A8106

PC Connection Kit

RS-232 to RS-485 adapter with RJ45 and DB9 female connectors

 

 

RJ45 to DB9 adapter for use with an ATV58 controller

 

 

Cable adapter for use with an ATV11 controller, VW3A11301

 

 

 

 

 

Includes the following to connect a Jornada or iPAQ PPC to an ATV11, ATV28, ATV58, or ATS48

 

 

controller:

 

PPC Connection Kit

1/2 m cable with RJ45 connectors

VW3A8111

RS-232 to RS-485 adapter with RJ45 and DB9 female connectors

 

 

 

RJ45 to DB9 adapter for use with an ATV58 controller

 

 

Cable adapter for use with an ATV11 controller, VW3A11301

 

 

 

 

 

This kit allows RS-485 multidrop serial link connection to PLCs, man-machine terminals. It is

 

 

connected in place of the keypad display, and therefore prevents the use of the keypad display

 

RS-485 Connection Kit

at the same time that the ATV58 TRX controller is connected to PLCs. The kit includes a 3-meter

VW3A58306U

 

(9.8 foot) cable with one male 9-pin SUB-D connector and one male 15-pin SUB-D connector;

 

 

and a manual.

 

 

 

 

Magelis Terminal

This option is used with RS-485 connection kit. A cable, XBT2908 is included in the kit.

XBTHM017010A8

 

 

 

 

I/O EXTENSION CARDS

Overview of I/O Extension Cards

The ATV58 TRX controller can be specially adapted for certain applications by installing an I/O extension card. One I/O extension card can be mounted into the ATV58 TRX drive controller. Space is already provided in the controller for the card; no retrofitting or additional panel space is required. Three models are available:

I/O Extension Cards

I/O Extension Card with Analog Input (VW3A58201U).

 

• I/O Extension Card with Encoder Inputs (VW3A58202U).

 

Pump Switching Option Card (VW3A58210U).

If these I/O extension cards do not meet your needs, Schneider Electric can design and supply customer-specific I/O extension cards, incorporating both hardware functions (I/O) and software functions.

A 115 Vac logic input module (VW3A58275U) is available for applications requiring 115 Vac control circuits.

The following sections describe the I/O options in greater detail.

26

© 2000–2003 Schneider Electric All Rights Reserved

 

09/2003

 

 

 

 

Page 26
Image 26
Schneider Electric 58 TRX manual Summary of User Interface Options and I/O Extension Cards, Overview of I/O Extension Cards